BRISTLE BLASTER
CORDLESS
b.
For Bristle Blaster
c.
Before you attach the battery to operate the tool, you must check that it is possible
to actuate the dead man's switch correctly and that the switch returns to the "OFF"
position when you release the pressure on the dead man's switch.
d.
To start the tool, you must release the safety clip by pushing it backwards and push
the dead man's switch (Figure 8).
Figure 8
e.
To stop the tool, you must simply release the pressure on the dead man's switch.
When attaching the battery ensure the dead man's switch is not activated (Figure 9).
Figure 9
f.
Hold tool by the tool body and the vertical handle at the same time.
g.
To obtain the best performance, ensure the Accelerator Bar is maintained
approximalely 10mm from the work surface. If the Accelerator Bar is too far from the
surface, the performance will drop significantly. See Figure 4. For a more detailed
description of the function of the Bristle Blaster
h.
Always work with adequate contact pressure. Excessive contact pressure will limit
the performance and cause damage to the MontiPower Bristle Blaster
tooth belt.
7. Use
7.1
Setting speed
The rotating speed is preset and fixed at 2,300 rpm to ensure optimal performance.
The VTC electronics make material-compatible work possible and an almost
constant speed, even under load.
®
stainless steel belt only use stainless steel Accelerator Bar.
®
visit
www.montipower.com
EN
®
Belt and
11