WARNING!
- Do not allow the starter grip to snap back. Return it slowly by hand.
- Grasp the carrying handle firmly to prevent the generator from falling over when pulling the
starting grip.
NOTICE:
- If the engine stops and will not restart, check the engine oil level before troubleshooting other
areas.
- Make sure the ECON switch is OFF before turning on the connected device.
Primer Bulb (For CI 2000 / CI 3000 only)
The primer bulb is used for bringing small amounts of gasoline to the throat opening of the carbu-
retor. The problem is that sometimes the generator cannot start because the fuel cannot reach the
carburetor (Refer to Fig. 4.3.).
Procedure for using the primer bulb
a)
Set the choke rocker in the OPEN position
b)
Push the primer bulb 15 to 20 times
c)
Move the choke rocker to the CLOSE position and start the engine
4.2
USING THE GENERATOR SET
WARNING!
Connections for standby power to a building's electrical system must be done by a qualified
electrician and must comply with all applicable laws and electrical codes. Improper connections
may cause serious injuries to electrical workers during power outage, and when the utility power
is restored, the generator may explode or cause fires.
WARNING!
- To prevent electrical shock from faulty appliances, the generator should be grounded.
- Limit operation requiring maximum power to 30 minutes.
- Do not exceed the current limit specified for any one receptacle.
- Do not connect the generator to a household circuit.
WARNING!
- Do not modify or use the generator for other purpose than it is intended for.
- When an extension cable is required, be sure to use a rubber sheathed flexible cable.
- Limit length of extension cables: 60m for cables of 1.5mm
2
and 100m for cables of 2.5mm
GB
2
.