NOTICE
The following points must be observed in order to avoid motor
malfunctions:
–
The control line should be correctly installed by a specialist.
Assembly parallel to power lines or their load should be
avoided.
–
Should the control lines be extended, dangerous voltages
can occur at the digital input. These should be avoided with
isolation.
–
The power cables for various inputs should not be connected
to the same supply line.
Default setting:
Speed:
Ventilation speed:
Ventilation time:
Speed which can be set:
Ventilation time which can be
set:
External controlling:
Switching behaviour input "0":
The software version "-rX.X-" is displayed briefly when the
supply voltage is switched on.
09|2019
1 = 600 rpm
2 = 1100 rpm
3 = 1800 rpm
= 1800 rpm
= 5 minutes
600 –1800 rpm (in 10 rpm
steps)
oFF, 1 – 10 min. (in 1 min.
steps)
oFF
0 cl
User interface:
(1) LED display: displays the
current speed of the motor.
(2)
: selection of the preset
speeds.
(3)
: to display the current
consumption and select the
parameters in the setup.
(4)
: to set the parameters.
(5)
: to change the speed
.
(6)
: to stop the motor.
EN 17