Fault
Pump transports is re-
ducing or transported
quantity is too low
Our Kärcher branch will be pleased to help you further in the case of questions or
faults. See address on the reverse.
Voltage
Frequency
Output P
nom
Max. flow rate*
Max. Suction height
Max. pressure
Max. flow height
Max. delivery tempera-
ture
Max. grain size of the
dirt particles that can be
transported
Pump type
Values determined as per EN ISO 20361
Sound pressure level
L
pA
Cause
Suction area blocked
The quantity transported by
the pump depends on the
transport height and the con-
nected periphery
Cross section on the deliv-
ery side constricted, e.g. due
to valve/ball valve that is not
completely opened.
Hose on the delivery side is
kinked.
Specifications
BP 2 Garden BP 3 Garden /
V
230 - 240
Hz
50
W
700
l/h
3000
m
8
MPa
0,35
(bar)
(3,5)
m
35
°C
35,0
mm
1,0
Jet
dB(A)
57
– 8
EN
Remedy
Pull out the mains plug
and clean the suction
area
Keep max. flow height,
see technical data. If nec-
essary, select a different
hose diameter or hose
length.
Completely open the
valve/ball valve.
Remove kinks from the
hose.
BP 3 Garden
Set Plus
230 - 240
50
800
3500
8
0,4
(4,0)
40
35,0
1,0
Jet
61
BP 4 Garden
Set
230 - 240
50
1000
4000
8
0,45
(4,5)
45
35,0
1,0
Jet
60
23