Cleveland PS20W Guide Du Propriétaire page 24

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING CONTINUED
SYMPTOM
The fire extinguishes and the
power shuts off.
The fire extinguishes and the
power shuts off (continued).
The circulation blower
continues to operate after
the stove is cool and the fuel
consumption has ceased.
The stove is not circulating
a sufficient volume of
sufficiently hot air.
Cleveland Iron Works Wood Pellet Fire Stove
CAUSE
No fuel in Pellet
Hopper.
1. Unplug the unit so that it will not start suddenly
Auger is blocked
2. Check that the auger is not blocked. If it is blocked,
or jammed or
disconnected.
3. Check that the auger screw fastening the auger to
The feeding speed
1. Decrease the fan's speed to decrease the rate of
is too low to
support the rate of
2. Increase the feeding speed.
combustion.
The 30
o
C
1. Check that wires to the switch are sufficiently
temperature switch
has triggered.
2. Replace the 30
Requested
temperature has
been reached.
The 30
C
1. Check that wires to the switch are sufficiently
o
temperature switch
has triggered.
2. Replace the 30
The fuel is
inadequate.
The circulating
1. If the blower is broken, change out the blower
blower is set
2. If the mother board which connects to the blower
too slow or is
compromised.
Heat exchange
tubes or flue pass is
dirty.
24
SOLUTION
Add Fuel to Pellet Hopper.
and then unblock the auger.
remove the cause of the jamming.
the motor is secure.
combustion.
connected.
C temperature switch.
o
This is normal "ECO" mode behavior. The stove will
automatically switch on once the ambient room
temperature drops below the temperature that the
stove is set to maintain.
connected.
o
C temperature switch.
Use pellet fuel specified by this manual.
is broken, change out the mother board.
Clean the heat exchanger tubes or flue pass.
Operating Instructions and Owner's Manual

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

F500215

Table des Matières