LINED MASONRY CHIMNEY INSTRUCTIONS &
DIAGRAM
This stove is designed to be vented through a masonry
chimney which conforms to local building codes, fire
codes, and latest edition of NFPA 21 1 US or CAN/
CSA-B365.
1. If the connection piping from the stove to a
masonry chimney is made through a combustible
wall, consult a qualified mason or chimney dealer
for consultation. To ensure safety, the installation
should only be done by a qualified installer. The
installation must conform to the regulations
established by local fire codes and building codes
2. The chimney connection
the chimney connector pipes, such as the figure
below illustrates.
Correct
Figure 10
Connection Pipe & Chimney Connection
3. If there is an opening at the base of the chimney it
must be closed tightly.
MANUFACTURED CHIMNEY INSTRUCTIONS &
DIAGRAM
WARNING: DO NOT USE SINGLE-WALL
CONNECTION PIPE AS A CHIMNEY.
This stove is designed to be used with either a UL
103HT (US)/ULC-S629 (CAN) listed manufactured
chimney or an approved lined masonry chimney. Not all
manufactured chimney are UL103 HT/ULC-S629 listed.
Home centers, hardware stores, HVAC supply stores,
and the Online websites of chimney manufacturers
will be able to provide stove pipe that is rated to these
standards.
This listing indicates that the Chimney is rated for high
temperatures up to 2100 °F (1 149 °C)
Only use components that all come from the same
manufacturer. Do not mix brands of components for
the same ventilation system.
The following figures illustrate various methods and
requirements of using a manufactured chimney and
connection pipes to vent the stove.
Cleveland Iron Works Wood Pellet Fire Stove
must not be obstructed by
Wrong
Wrong
Double-wall UL 103
High Temperature
Chimney Pipe
10
Floor Protector
Figure 11
Manufactured Chimney through Wall
UL 103 Chimney
Joist Shield
/ Firestop
Chimney Support
Double-wall UL 103 High
Temperature Chimney Pipe
Floor
Protector
Figure 12
Manufactured Chimney through Attic
1 1
Operating Instructions and Owner's Manual
Wall
Termination
Thimble
Cap
6 in
(152mm)
Minimum
6 in
(152mm)
Minimum
Horizontal
Termination
Clean Out T
Cap
Mandatory Chimney Cap &
Spark Arrestor
Storm Collar & Roof
Flashing per Local
Mobile Home Building
Codes
Attic Insulation
Shield
Clean Out T
Bolted to floor