5.4

Operating position

The burner is designed to work only in the
positions 1, 2, 3, 4, and 5.
Installation 1 is preferable, as it is the only one that
ATTENTION
allows the maintenance operations as described
in this manual.
Installations 2, 3, 4, and 5, allow operation, but
make maintenance more difficult (Fig. 5).
1
5.5

Generator plate

Pierce the closing plate of the combustion chamber, as in Fig. 6.
The position of the threaded holes may be marked using the
gasket joint supplied with the burner.
mm
D1
RX 70 S/PV
145
5.6

Securing the burner to the boiler

Provide an adequate lifting system.
For the installation proceed as follows:
 Fix the burner 1)(Fig. 7) to the boiler door 2) using the 4
screws and (if necessary) the 4 nuts supplied to the standard
equipment, interposing the insulating flange gasket 3).
2
W1
W2
R
130
150
11
Installation
Any other position could compromise the correct
operation of the appliance.
All the positions require the installation of the gas
valve with coils facing upwards or horizontally.
DANGER
Installation with the coils pointing downwards 6 is
absolutely forbidden.