Dip switch n°1-2-3: Select type of bollard.
Dip1
Dip2
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
Dip switch no. 4: Automatic reclosing on.
OFF: Off.
ON:
On with a pause time adjustable with the "T.PAUSA" trimmer, from 2 to 120 sec.
Dip switch no. 5: "START" and "CLOSE" commands enabled during the pause time.
OFF: Off.
ON:
On.
Dip switch no. 6: "START" command valid only if open activated fi rst.
OFF: Separate inputs.
ON:
Dependent inputs.
Dip switch no. 7: Closing command procedure.
OFF: Impulse operation.
ON:
Operates upon release.
Dip switch no. 8: Pre-fl ashing function on fl ashing light, traffi c light and AUX output
OFF: Disabled.
ON:
Before each lowering phase, it activates the fl ashing light and the AUX output for 2 seconds and before each
raising phase it activates the fl ashing light and the AUX output (adjustable with AUX trimmer) and alternates the
green and red lamps of the traffi c light for 0 to 10 seconds.
Dip switch no. 9: Led with device in downright position.
OFF: Steady light.
ON:
1 fl ash a second.
Dip switch no. 10: Led with device in upright position.
OFF: Steady light.
ON:
2 fl ashes a second.
See para. 5.3, "DEAD MAN CONTROL" section for more details.
T.AUX:
It adjusts the duration, from 0 to 10 seconds, of the pre- ashing function of the ashing light, traf c light and activation of the
clean AUX contact between terminals 17-18 before the bollard rises.
V.RAL:
it sets slowing down speed at the end of the closing manoeuvre.
Slowing down speed at the end of opening is factory set.
T. PAUSA: it sets pause time from 2 to 120 sec.
Use a QK-R02 radio receiver
9. CONNECTIONS FOR SIMULTANEOUS OPERATION
The control unit QK-CE220CT is used to operate up to a maximum of four bollards connected in parallel to thus obtain simultaneous ope-
ration with just one control panel.
Use a junction box with adequate protection rating to complete the connections between the bollards in order to avoid cumbersome joints
near the control panel.
MOTOR CABLES:
CONDENSER CABLES:
ELECTRIC BRAKE CABLES: Connect the WHITE cables of the electric brakes in parallel
LIGHT CABLES:
END-OF-TRAVEL CABLES:
BURGLAR CABLES:
HEATING ELEMENT CABLES: Connect the RED cables of the heating element in parallel, if envisaged.
6. DIP-SWITCH CONFIGURATION
Dip3
model
OFF
QK-CT210500 / QK-CT210500L / QK-CT210500LA
ON
QK-CT210500FX/ QK-CT210500LFX/ QK-CT210500LAFX
OFF
QK-CT210700/ QK-CT210700L / QK-CT210700LA (MODELS PURCHASED BEFORE 01/07/11)
QK-CT210700 / QK-CT210700L / QK-CT210700LA (MODELS PURCHASED AFTER 01/07/11)
ON
OFF
QK-CT115500/ QK-CT219500/ QK-CT219500L
ON
QK-CT193700L/ QK-CT219700/ QK-CT219700L
7. ADJUSTING THE TRIMMERS
8. RADIO RECEIVER
Connect them in parallel respecting the polarity of the motors and joining the black cables, the brown cables and the
blue cables together.
Connect the condensers (with which each bollard is equipped) in parallel between the black cables and the brown
cables of the motor cables.
Connect the YELLOW cables of the LED lamps in parallel.
Connect the GREEN cables of the opening end-of-travel devices in series.
Connect the ORANGE cables of the burglar device contact in series, if envisaged
- 16 -