FREE AUXILIARY CONTACT
17
It is used to avail of a N.O. clean contact with capacity of 250V 5A max., activated intermittently as N.O.-N.C. adjustable from 0
AUX
to 10 seconds before the bollard raises, throughout all movements and 2 seconds before lowering. It proves particulary useful
18
to command luminous and acoustic indicators.
OUTPUT FOR POWERING ACCESSORIES
19
24Vac 1A max. output to power safety or control devices once the system is completed.
20
FTC
21
PHOTOCELL INPUT
When the beam is interrupted the device will open during the closing phase.
COM
22
STOP
STOP INPUT
23
If this is activated in opening it stops the manoeuvre, leaving the no-parking device released.
A following start command opens the no-parking device unless it is already open in which case it will be closed.
COM
22
If the pause time has been programmed, a stop command eliminates automatic reclosing.
COM
OPENING LIMIT SWITCH INPUT
24
The device is equipped with an opening limit switch that, by means of a reed contact (green wires), guarantees switching of
FCA
the traf c light to the green "forward" light only when the no-parking device is down and the motor has stopped.
25
START
START INPUT
26
With the no-parking device up, opening is commanded during which other start impulses are not considered.
With the no-parking device down, a start command commands the closing manoeuvre during which, if another start command
is given, the opening manoeuvre is effected again.
COM
Con gure dip switches 4-5-6 so as to control the start commands according to system requirements.
29
APRI
OPENING INPUT
27
It commands opening of the device and also effects a safety function in that, if it is on permanently, it will not let the no-parking
device close. Connect either programmer clocks (if used) to this input for periodical opening/closing or metal detectors.
COM
The opening command can be managed in two different ways depending on how dip switch 6 is set.
29
CLOSING INPUT
CHIUDI
The device can be closed either by pressing the button or by releasing the command, depending on how dip switch 7 is set.
28
If you choose to release the command in order to close the device and if this input is on permanently, it will also perform a
COM
29
safety function until the command is freed.
FTC
21
CHIUDI
DEAD MAN CONTROL
28
The bollard lowering is semi-automatically controlled, whereas the switch should be pressed to raise it.
COM
A warning light connected to the electric brake output signals that raising has ended.
29
The raising control switch can be released when the warning light comes on.
11
Regulations prohibit controls via radio with dead-man logic
24V
3W max
12
HEATING ELEMENT
F
30
It supplies power to the 230V 100W heating element, part of the accessory QK-CTHEAT (red coloured wires) and recom-
N
mended when the no-parking device is used in particularly cold places.
31

5.5 BURGLAR ALARM (optional) or SHANK "UP" SENSOR (optional)

Bollards equipped with the BURGLAR ALARM accessory have a reed sensor installed under the ange. This sensor supplies a clean
N.C. contact to be connected to an external burglar alarm system that triggers if the bollard is tampered with. Bollards equipped with the
SHANK "UP" SENSOR accessory have a reed sensor that supplies a clean N.C. contact when the shank is raised completely.

5.3 INPUTS COMMAND TERMINAL BOARD CN3

5.4 TERMINAL BOARD FOR HEATING ELEMENT CN4

terminals 17 - 18 (AUX)
terminals 19 - 20 (24 Vac)
terminals 21 - 28 - 29 (CN3)
- 15 -
terminals 21 - 22 (FTC)
terminals 23 - 22 (STOP)
terminals 24 - 25 (FCA)
terminals 26 - 29 (START)
terminals 27 - 29 (OPEN)
terminals 28 - 29 (CLOSE)
terminals 30 - 31 (CN4)