Introduction; Main Features; Technical Specifications - quiko QK-CE220CT Instructions Pour L'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The control unit QK-CE220CT designed to control the QUIKO automatic bollards marks a step forward in the management
of automations for urban and civil furnishings. The choice of the various operating logics and the complete supply of inputs mean that
the control unit can be interfaced with many peripheral units which, based on the complexity requested, thus enabling the creation of a
state-of-the-art and modern access control system to manage vehicle traffi c. The microprocessor constantly controls lifting and lowering
movements enables the gradual deceleration at the end of the movement, which makes the stem travel whisper-quiet and appealing.
- Microprocessor logic.
- LEDs that show the state of the inputs on the terminal board.
- Pull out terminal boards with safety pitch for power connections.
- Built-in traf c light control.
- Timed free contact available.
- Protected from over voltages and radio interference by means of a net lter and varistors.
- Suitable for controlling a maximum of 4 no-parking devices simultaneously.
CN1: Power terminal board
CN2: Low output voltage command terminal board
CN3: Inputs command terminal board
CN4: Heating elements terminal board
CN5: Transformer connector
CN6: 230V power supply terminal board
CONTROL UNIT
QK-CE220CT

1. INTRODUCTION

2. MAIN FEATURES

CN16: Programmer connection
S1: Dip switch
TR1, TR2 and TR3: Adjustment trimmers
P1: START key
P2: RESET key
F1: 6.3 A line fuse

3. TECHNICAL SPECIFICATIONS

- Power supply:
- Motor outlet:
- Electric brake output:
- Traf c light output:
- Flashing light output:
- LED lights output:
- 24Vac output for accessories: 1A, 24W
- Operating temperature:
- Box dimensions:
- Protection level:
230Vac +/- 10% 50Hz (other voltages available on request)
230Vac; 1000W max (equivalent to four motors)
24Vdc inrush and 12Vdc at steady condition
230Vac 2x40W max
230Vac 80W max
24Vac 24W max
-15/+60 °C
200 x 275 x 130 mm
IP54
- 13 -
EN
F3: 2 A E.F. fuse
F4: 2 A 24 Vac out fuse
F2: 250mA logic fuse
CM: Connector for capacitor

Publicité