Sauna heater – separate control panel combinations
Heater
model
230-240V 3~
230-240V~
SO 6
TS 30,
*TS 30,
SO8,
CC 10 / RB 30,
CC 10 / RB 30,
WM 10, EP 100
CC 50 / RB 30,
CC 50 / RB 30,
CC 100/RB30
CC 100 / RB30
TS 58 -12 RB
-
CC 10 / RB 60,
EH-15
CC 50 / RB 60
CC100 / RB 60
TS 58 -12 RB
-
CC 10 / RB 60,
EZ 22,5
CC 50 / RB 60
CC100 / RB 60
*) 10 kW not approwed for single-phase in Europe.
Installation of separate control panels.
Must be assembled outside the sauna. Control panel type TS or CC + RB is
required for Tylö EP, EH and EZ heaters.
TS-type control panels
TS panels are thermally operated and have a patented divided output.
They can either be surface-mounted or recessed for a flush fit (fig. 11). It
is essential to fit insulation behind control panels recessed into the wall.
The standard length of the capillary tube is 1850 mm, but a 5000 mm
capillary tube is also available.
Installing a sensor for a TS control panel (fig. 10). A = capillary tube.
B = sensor holder. C = plastic holder for capillary tube. D = sensor that is
installed 1500 mm above floor level (fig. 9 and 10, not above the sauna
heater).
Extra equipment for the TS control panel.
Locking cover in transparent plastic to fit over the control panel. Available
in designs to prevent unauthorised interference with time and temperature
settings, or temperature only.
Figs. 17–21, 25, 26, 29 Wiring diagrams.
(With sauna heater EP, EH, EZ and control panel TS).
1 = sauna heater. 2 = control panel. 3 = relay box.
Check the heater's type identification plate to ensure that the heater is
connected to the right voltage. Don't forget – The installation must be
earthed!
Remote control operation.
TS control panels use contactors for remote control operation.
CC control panels.
Instructions: included with the control panel.
Can be installed at any distance from the sauna room.
CC panels are electronically operated and are available in the following
models:
CC 10-3. Manual and automatic on/off. A maximum of three hours'
running time, 10 hours' pre-set time.
CC 50-3. Manual and automatic on/off. A maximum of three hours'
running time, 10 hours' pre-set time.
CC 50-12. Manual and automatic on/off. A maximum of 12 hours' running
time, 10 hours' pre-set time.
CC 100-3. Manual and automatic on/off. A maximum of three hours'
running time, 24 hours' pre-set time.
CC 100-12. Manual and automatic on/off. A maximum of 12 hours'
running time, 24 hours' pre-set time.
CC 100-0. Built-in weekly timer. A maximum of 12 hours' continuous
running time.
Placement of the thermistor (sensor).
1500 mm above floor level (not above the sauna heater).
The thermistor wire can be lengthened outside of the sauna with a partially
enclosed low-voltage cable (2-core).
The thermometer in the sauna should be placed at a height so that the
temperature corresponds exactly to the numbers displayed on the CC
50/CC 100.
Note: If necessary seal the hole in the wall behind the thermistor.
Relay box (RB).
Installed outside the sauna at any distance from it. The relay box may not
be placed closer than one metre from the CC 10/ CC 50/ CC 100.
Partially enclosed low-voltage cable (6-core).
The control cable between the CC 10/ CC 50/ CC 100 and the relay box
must be a partially enclosed low-voltage cable (6-core). Connect the
shielding cable to plinth 12 in the relay box.
6
Suitable control panel
400-415V 3~
200-208V~
TS 16, TS 30,
*TS 30,
CC 10 / RB 30,
CC 10 / RB 30,
CC 50 / RB 30,
CC 50 / RB 30,
CC 100 / RB30
CC 100 / RB30
TS 30,
-
CC 10 / RB 30,
CC 50 / RB 30,
CC 100 / RB 30
TS 58 -12 RB
-
CC 10 / RB 60,
CC 50 / RB 60
CC100 / RB 60
Lighting.
Connect the lighting according to the wiring diagram.
200-208V 3~
Remote control operation.
TS 30,
CC control panels are already prepared for remote-control operation from
CC 10 / RB 30,
one or more locations.
CC 50 / RB 30,
CC 100 / RB 30
Option: external on/off-switch (instantaneous).
TS 58 -12 RB
Can be placed at any distance from the sauna. Connected with a low-
CC 10 / RB 60,
CC 50 / RB 60
voltage cable to the CC 10/ CC 50/ CC 100 – see the wiring diagram. If
CC100 / RB 60
there are several external on/off switches, they should be parallel-
TS 58 -12 RB
connected.
CC 10 / RB 60,
CC 50 / RB 60
Connection to a central computer.
CC100 / RB 60
The control panel can also be connected to a central computer, which
gives a brief impulse (closure) between plinths 19 and 20 in the CC 10/
CC 50/ CC 100. The maximum permitted connection time for the sauna is
12 hours.
An instruction guide is included with the control panel.
Figs. 22, 23, 27, 30 Wiring diagrams.
(With sauna heater EP, EH, EZ and control panel CC).
1 = sauna heater. 2 = thermistor (sensor). 3 = control panel.
4 = external on/off switch (if any). 5 = relay box.
Check the heater's type identification plate to ensure that the heater is
connected to the right voltage. Don't forget – The installation must be
earthed!
Unusual voltages or number of phases.
Before connecting the heater to a different voltage or number of phases
than those described in the wiring diagram, contact Tylö Customer
Service.
BUILDING INSTRUCTIONS
The importance of correct sauna ventilation.
Incorrect sauna ventilation can result in hot floors and benches, scorched
walls and ceilings (the temperature limit control is triggered)! So we do
urge you to follow our instructions for sauna ventilation carefully.
Adjust the air outlet to evacuate 6–8 cu.m. of air per person, per hour,
when the sauna is in operation.
Mechanical sauna ventilation is not to be recommended, as the forced air
supply can cause a fire hazard through the wooden panelling drying out.
Fig. 12. Sauna heater and door on the same wall.
The "air circulation" created by the door should work together with the hot
air generated by the heater. To facilitate this, the heater should be placed
on the same wall as the door (If exceptional circumstances require the
heater to be fitted to a side wall, make sure it is located in close proximity
to the wall with the door).
Fig. 13. Inlet vent always directly below the heater.
The inlet vent should be driven straight through the wall directly below the
centre of the heater. The cross-section of the vent for a family sauna is
approx. 125 Sq.cm., for larger saunas approx. 300 sq.cm.
Fig. 14. The outlet vent should never discharge
directly into the open air.
Position the air inlet and outlet vents as far away from one another as
possible (diagonally opposite). The outlet vent should be located high on a
wall or in the ceiling, and should have the same cross-section area as the
inlet vent.
Spent air should always be led back into the same room from which it is
drawn into the sauna – it must never be discharged directly into the open
air. In this way, the air flowing from the sauna is continually being
replenished in the room outside. This thermal ventilation method always
works, no matter whether the pressure in adjacent rooms is negative or
positive.
If there is a gap above the sauna ceiling, do not seal it. To ventilate a
cavity above the sauna, drill or cut at least one ventilation hole into the
cavity through the wall on which the sauna door is located.
Alt. A: Outlet vent through the sauna wall (seen from above). The vent is
placed high up, near the ceiling.
Alt. B: Outlet vent through the cavity above the sauna ceiling (seen from
the side).
Alt. C: Outlet vent through a drum under the ceiling in the sauna (seen
from the side). The outlet duct should be placed at an angle between the
ceiling and the wall. The drum can be built of wooden panelling and have
the same area as the outlet vent.