Administrator code:
modifying and deleting user codes, performing operational tests on the detectors and accessing the
alarm unit setup menu
Installer code:
Modifiable code reserved for the installer to access programming of the alarm unit
This code cannot be used to deactivate supervision by your alarm unit.
Event log:
All the operations performed on the alarm unit are recorded in the event log with the date
and time: activation and deactivation of supervision with the number of the user code used, 230 V line
power failure, alarm, installer action, etc.
Time delay on entry:
deactivate supervision.
Time delay on exit:
activating supervision.
SOS:
Call for help made from the alarm unit, keypad or remote control unit.
Prealarm:
Detectors can be installed outside the area supervised. Whenever one of these detectors
is trigger, a prealarm message "Warning, protected site" is broadcast. This deterrent system does
not set off an alarm.
Line power supervision:
case of a line power failure lasting one hour, the alarm unit broadcasts the message " Power cut "
and calls the call reception centre to report it.
Battery supervision:
as the charge level falls below a threshold, a message is output.
Backup battery:
failure. When the battery is low, the alarm unit calls the call reception centre to report this if the fault
lasts more than 30 minutes.
Cyclic test:
The alarm unit may be programmed so that this test cyclically checks operation of the
telephone line. Such calls are generally programmed at night.
Forced operation:
alarm status. This detector is then inhibited and the event is recorded in the event log.
Indoor siren
: The indoor siren sounds for 90 seconds during an alarm. If the siren was triggered by
mistake, you can stop it by deactivating supervision.
Self-protection:
The integrity of your alarm system is continuously monitored. An alarm and a call
are triggered by an attempt to open or tamper with the system.
Modem transmitter
telephone link with the call reception centre. Alarm transmission is not stopped by deactivating the
alarm unit after triggering of an alarm.
Fraudulent keypad use:
centre and disables the keypad for two minutes.
Chime:
When the alarm unit is off, certain detectors can generate a chime type signal when triggered.
This function can be enabled or inhibited from the front panel of the alarm unit.
Voice message:
The alarm unit is equipped with a digital recorder allowing one of the users to
record a voice message lasting 15 seconds at most. When the alarm unit is deactivated, a visual and
audio signal alerts the other users that a message is present and prompts them to consult the
message.
Voice synthesis:
The alarm unit is equipped with a voice synthesis which guides the users through
their various handlings.
The administrator code is a unique confidential code used for creating,
.
Programmable time delay allowing the user to access the alarm unit and
Programmable time delay allowing the user to leave the premises after
The alarm unit continuously monitors presence of 230 V line power. In
The charge level of the detector batteries is continuously monitored. As soon
The backup battery keeps the alarm unit operational in case of a line power
You can force activation of supervision by the alarm unit even if a detector is in
: The alarm unit is equipped with a modem transmitter which handles the
Entry of three incorrect codes generates a call to the call reception
- 15 -
.