be replaced by the manufac-
turer, a customer service agent
of the same or a similarly quali-
fied person in order to prevent
hazards.
•
Do not pull the plug from the
socket by the cable. Protect
the cable from heat, oil and
sharp edges.
•
Do not carry or fix the equip-
ment by the cable.
•
Use only extension cables that
are protected from spray wa-
ter and designed for outdoor
use. Always fully unroll a cable
drum before use. Check the
cable for damage.
•
Before any work on the equip-
ment, during work breaks and
in the case of non-use, remove
the plug from the socket.
•
The cross-section of mains
connection lines must be no
smaller than rubber hose lines
with the designation H07RN-F.
Initial Operation
Assembly
•
To permanently install the home wa-
ter dispenser, screw it to the ground.
Screwing it to a fixing panel will pre-
vent the appliance from moving.
Mind not to obstruct the access to the
draining screw (
All screw connections must be fit-
ted with a sealing strip if the dome-
stic water pump is used inside the
house.
Mains Connection
The pump you have purchases is already
fitted with an earthed plug. The pump is
A
8).
intended for connection to an earthed
socket at 230 V ~ 50Hz.
Setting up
•
Place the unit on a firm, horizontal,
non-flooding surface.
•
Always put up the domestic water sys-
tem at a point higher than the water
surface you wish to pump water from.
Where this is impossible, install a low
pressure-resistant shut-off implement
between the appliance and the suc-
tion hose (Available from specialist
retailers).
The pressure vessel (
show an air pressure of 0.15 MPa
(1.5 bar) in an unused condition.
Check the air pressure before
initial start-up using the pressure
A
gauge (
9).
•
Regulate the pressure in the pressure
vessel (5) by removing the protective
cap for the air valve (14), undoing the
valve protective cap (15) and pumping
air into the pressure vessel via the air
valve (16) or allowing air to vent.
Connecting the hoses
On the suction side, attach a hose
with reflow stopper and install a
prefilter (Available from specialist
retailers). On the suction side, do
not use any quick-action connec-
tion systems.
All screw connections must be fit-
ted with a sealing strip if the dome-
stic water pump is used inside the
house.
Air in the suction hose will stop
the house water dispenser from
working properly. Observe the di-
GB
A
5) must
25