Initial Operation

Setting up

Place the device on a solid, horizontal
base which is also safe from flooding.
The horizontal alignment can be ad-
justed with the help of the jack screw
(
9).
If you would like to install the device,
screw it together with the base. A
screw connection with a fastening
plate also prevents the device from
slipping.
By doing so, ensure a free access to
the drain screw (
In principle, place the device higher
than the water surface out of which
you would like to pump.
If this is not possible, install a vacuum
resistant shut-off unit between the de-
vice and the suction line (available at
specialised traders or DIY stores).

Mains Connection

The pump you have purchases is already
fitted with an earthed plug. The equipment
is designed for connection to an earthed
wall socket with a residual current operat-
ed device (RCD switch) at 230 V ~ 50Hz.
Connect the mains connection cable (
8) to the power supply.
Connecting the lines
Please use a suction device with
a suction filter, strainer and check
valve so that water does not enter
the switched off pump and in order
to prevent damages to the pump
caused by contaminations.
10).
Do not use any connection systems
with quick connectors on the suction
side.
The suction line can either be a pipe-
line or a flexible hose assembly. It
must have a minimum cross-section
of 25 mm. In the case of fixed pipe-
lines or a suction height of more than
4 m, the use of larger cross-section is
recommended.
Lay the suction line rising from the
withdrawal of water to the pump (see
image
).
When assembling the suction and
pressure line make sure that no me-
chanical pressure or tension is placed
on the device. Please ask your spe-
cialist trader.
1.
Remove the cover cap (1) at the
water inlet (2).
2.
Assemble the suction line at the
supports of the water inlet (2)
(1" internal thread) Screw this
down until it is airtight.
3.
Remove the cover cap (4) at the
water outlet (5).
4.
Assemble the suction line at the
supports of the water outlet (5)
(1" internal thread) Screw this
down until it is airtight.
The function of the garden pump is
not guaranteed through air in the
suction line.

Filling the pump

The pump must be filled with water prior
to each commissioning. This guarantees
an immediate start up. Dry running dam-
ages the pump.