TECHNICAL DATA TABLE
DESCRIPTION
Rated tank capacity
Insulation thickness
Type of internal tank protection
Type of corrosion protection
Maximum operating pressure
Diameter of hydraulic connections
Diameter of condensate drainage connection
Diameter of air exhaust/intake pipes
Minimum water hardness
Minimum conductivity of the water
Weight when empty
Heating bottom circuit exchange surface
Heating top circuit exchange surface
Max water temperature with external integration
HEAT PUMP
Average electrical power consumption
Max. electrical power consumption
Quantity of refrigerant fluid (R134a)
Quantity of fluorinated greenhauses gases (R134a)
Global warning potential (R134a)
Max. pressure of refrigerating circuit (low-pressure side)
Max. pressure of refrigerating circuit (high-pressure side)
Max. water temperature with heat pump
EN 16147 (
A
)
COP (
A
)
Heating time (
A
)
Heating energy consumption (
A
Max. amount of hot water in a single intake Vmax (
Pes (
A
)
Tapping (
A
)
812/2013 – 814/2013 (
B
)
Qelec (
B
)
ηwh (
B
)
Mixed water at 40°C V40 (
B
)
Temperature setting (
B
)
Annual electricity consuption (average climatic condition) (
Load prifile (
B
)
Indoor sound power level (
C
)
HEATING ELEMENT
Heating element power
Max. water temperature with heating element
Max. current consumption
POWER SUPPLY
Voltage / max. power consumption
Frequency
Protection rating
AIR SIDE
Standard air flow rate (automatic modulating control)
Available static pressure
Minimum volume of room of installation (
Minimum ceiling height of room of installation (
Min. temperature of room of installation
Max. temperature of room of installation
Minimum air temperature (w.b. a 90% u.r.) (
Maximum air temperature (w.b. a 90% u.r.) (
Further energy data is shown in the Product Data Sheet (Annex A) which is an integral part of this booklet. Products that are not provided with a label
and corresponding product fiche for a combination of water heater and solar devices, as specified by Regulation 812/2013, are not intended to be used
for these kind of combinations.
(A) Values obtained with outdoor air temperature of 7°C and relative humidity of 87%, inlet water temperature of 10°C and temperature set at 55°C (as per the provisions in EN 16147 and CDC 103-15/C-2018).
Ducted product Ø200 mm.
(B) Values obtained with outdoor air temperature of 7°C and relative humidity of 87%, inlet water temperature of 10°C and temperature set at 55°C (as per the provisions of 2014/C 207/03 - transitional
methods of measurement and calculation). Ducted product Ø200 mm.
(C) Values obtained from the average of the results as per the provisions in EN 12102-2. Ducted product Ø200 mm.
(D) Value that guarantees the correct operation and easy maintenance with non-ducted products. The correct operation of the product is nevertheless guaranteed up to a minimum height of 2.090 m.
(E) Beyond the heat pump temperature range of operation, heating of the water is ensured by integration (as per provisions of EN 16147).
)
A
), delivered at 55°C
B
)
D
)
D
)
E
)
E
)
Unit
200
l
200
mm
Titanium impressed current anode + disposable
MPa
II
mm
mm
°F
μS/cm
kg
90
m²
-
m²
-
°C
-
W
W
kg
Tonn. CO
eq.
2
GWP
MPa
MPa
°C
3,10
h:min
03:59
kWh
2,478
l
256
W
21
L
kWh
3,72
%
130,0
l
256
°C
55
kWh/year
790
L
dB(A)
55
V / W
Check product specification label
°C
A
V / W
Check product specification label
Hz
m³/h
Pa
m³
m
1,940
°C
°C
°C
°C
250 TWIN
250
250 SYS
SYS
240
250
245
≈ 50
Enamelling
magnesium anode
0,6
G 3/4 M
14
150-160-200
12
150
130
95
115
0,65
-
0,65
0,65
-
-
75
-
75
700
900
1,3
1,859
1430
1
2,7
62
3,21
3,35
3,14
05:15
05:23
05:24
3,224
3,346
3,264
325
336
333
25
22
23
XL
XL
XL
5,86
5,66
6,04
133,0
138,0
129,0
325
336
333
55
55
55
1256
1215
1299
XL
XL
XL
55
55
55
75
11,48
50
IPX4
650
230
30
2,200
2,200
2,200
1
42
-10
42
23 / EN