Adjust the minimum burner setting:
3
When changing from one gas type to another, the
minimum valve output must also be correct,
considering that in this position the flame must be about
5⁄32" (4 mm) long and must remain lit even when the knob
is turned quickly from the maximum to the minimum
position.
The adjustment is performed with the burner lit, as
follows:
Turn the knob to the minimum position.
Remove the knob.
Turn the adjustment screw to the correct setting
with a screwdriver (Fig.17).
For LP/Propane gas, tighten the adjustment screw completely.
Re-test for leaks:
4
Repeat the steps under 'Leak-testing the cooktop' .
Fill in/affix the gas conversion labels:
5
After completing the gas conversion, fill in the gas conversion labels (supplied with the
conversion kit).
Affix the adhesive/polyester label near the model/serial rating plate on the underside of
the basepan.
Affix the paper label into the appropriate frame at the front of this manual, under the
duplicate data (model/serial/rating) plate.
Gas rate summary
Nominal
CG122 models
power
Burners
BTU/hr
Semi-rapid
6000
Rapid
10000
Nominal
CG244 models
power
Burners
BTU/hr
Auxiliary
Semi-rapid
Triple-ring wok
11500
Reduced
power
BTU/hr
1500
2000
Reduced
power
BTU/hr
3500
1000
6000
1500
5200
Installation instructions
Fig. 17 Adjusting the minimum burner setting
LP/PROPANE
11" W.C.P.
injector
By-pass
[1/100 mm]
[1/100 mm]
72
34
94
44
LP/PROPANE
11" W.C.P.
injector
By-pass
[1/100 mm]
[1/100 mm]
55
27
72
34
100
65
Adjustment screw
NATURAL GAS
4" W.C.P.
injector
By-pass
[1/100 mm]
[1/100 mm]
118
adjustable
155
adjustable
NATURAL GAS
4" W.C.P.
injector
By-pass
[1/100 mm]
[1/100 mm]
90
adjustable
118
adjustable
165
adjustable
19
US CA