Installation instructions
20
US CA
Electrical connection and requirements
Important!
Plug only into a grounded three-prong power outlet.
Do not remove the grounding prong.
Do not use an adapter.
If codes permit the use of a separate grounding wire, it is recommended that a qualified
electrician determine that the ground path is adequate.
Check with a qualified electrician if you are not sure whether the cooktop is properly grounded.
Do NOT ground to a gas pipe.
See 'Safety and warnings' for additional electrical requirements.
A 120-volt, 60-Hz, AC-only, 15 A, fused electrical supply is required.
A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit
serving only this appliance be provided.
The power outlet must be checked by a qualified electrician to see if it is wired with correct
polarity.
3-prong polarized
3-prong
ground-type outlet
ground plug
power
supply cable
ground
prong
Fig. 18 Recommended grounding method
Wiring digrams
CA
CA
M
N
L
CA
CA
CA
M
N
L
CA
A
A
PA
PA
Fig. 19 Wiring diagram - CG122 models
Fig. 20 Wiring diagram - CG244 models