To enter this mode press the two buttons P1 and P2 at the same time, at this point LED DL10 will turn on with a steady
orange light indicating the deadman setup mode. Release buttons. (see figure above).
Now, as you can see in the figure below, the button P1 controls the motor in cyclic mode. Simply hold down the button to
make the motor move and this will reverse the direction with each new pressure, thus having complete control of the two
directions.
The LED DL10 colour will indicate the direction of the motor in order to check also the connections of the respective motors:
Red = closing direction
To enter the programming of the stroke, keep the button P1 pressed until the LED DL10 prg starts flashing in green (first
flashing frequency). Release button P1, then follow the programming steps below. Programming ends when LED DL10 turns
off.
Start the procedure with closed gate.
Besides the P2 button of the control unit, in the stroke saving procedure, you can use also the button saved as SEQ
on the remote control or the button connected to the SEQ input.
1ST PULSE
PRESS P2 TO START THE SAVING
OPERATION, IF THE GATE IS NOT AT THE
CLOSING LIMIT SWITCH THE FIRST
MANOEUVRE TO CARRY OUT WOULD BE TO
SLOWLY CLOSE THE GATE TO POSITION IT
PRESS P2 TO SET THE PARTIAL
OPENING POINT.
WARNING!
If you do not wish to use the slowdown settings, do not perform the steps indicated by the asterisk. Each time the
slowdown speed is changed, you have to repeat the saving to obtain the desired variations.
LBT0499 – DS41627-001 – FW 1.01 2020
Stroke saving procedure
RELEASE BUTTON P1 AS SOON AS LED DL10 STARTS FLASHING GREEN
SLOW FLASHING OF LED DL10 INDICATES THE WAITING FOR A PULSE
2ND PULSE
PRESS P2 TO SET THE STARTING
POINT FOR OPENING SLOWDOWN
THE CONTROL UNIT WILL NOW
AUTOMATICALLY PERFORM A COMPLETE
MANOEUVRE TO SAVE THE CURRENTS, AFTER
WHICH LED DL11 WILL FLASH QUICKLY AND
THEN TURN OFF INDICATING THE END OF
THE SAVING OPERATION.
MOTOR CLOSING AT SLOWDOWN
SPEED SET IN TRIMMER TR3
RED
MOTOR OPENING AT MAXIMUM
SPEED
GREE
N
3RD PULSE
PRESS P2 TO SET THE STARTING
POINT FOR CLOSING SLOWDOWN
Green = opening direction