INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTIONS
This cooktop does not require a neutral connection. If the cooktop is
to be completely enclosed in a cabinet, feed the cooktop cable
through the opening in the cabinet. Make the electrical connection
US
following the appropriate steps for your installation.
1
Disconnect the power supply.
2
Remove the junction box cover.
3
Connect the cooktop cable to the junction box through the
U.L.-listed conduit connector.
4
Connect the two black wires together with twist-on connectors.
5
Connect the two red wires together with twist-on connectors.
6
Connect electrical connection according to local codes and
ordinances.
If local codes PERMIT connecting cabinet-grounding
conductor to neutral white wire in the junction box:
7
Connect the green cooktop cable wire to the neutral (white)
wire in the junction box.
8
Replace the junction box cover.
or
If local codes DO NOT PERMIT connecting cabinet-grounding
conductor to neutral white wire in junction box:
7
Terminate neutral (white) wire in junction box.
8
Connect the green grounding cooktop cable wire to a grounded
wire in the junction box.
9
Replace the junction box cover.
or
If connecting to a four-wire electrical system:
7
Terminate neutral (white) wire in junction box.
8
Connect the green cooktop cable wire to the green grounding
wire in the junction box.
6
WARNING
Electrical Shock Hazard
Disconnect power before
servicing the product.
Failure to do so could result in
death or electrical shock.
junction box
red wires
white wire
green wire
junction box
red wires
green wires
cable from
power supply
black wires
U.L.-listed conduit
connector to cooktop
cable from
power supply
white wire
black wires
U.L.-listed conduit
connector to cooktop