INSTALLING THE COOKTOP
Place the cooktop into the cutout and tighten it with the supplied
clamps and screws.
These will cope with countertop thicknesses
in the two orientations shown below.
Do Not Overtighten
Clamping Bracket Screws
48" flexible conduit supplied
attached to product
WARNING
Beware of sharp edges.
Use the polystyrene ends
when carrying the product.
Failure to use caution could
result in minor injury or cuts.
5
3
/
" - 1
/
" when used
8
4
3
1
/
"
4
5
/
"
8
Cut Hazard
INSTALLATION INSTRUCTIONS
ELECTRICAL REQUIREMENTS
Your cooktop must be connected to the proper electrical voltage and
frequency as specified below.
Model
Power
Required
power supply
CE901/M
8.5kW
240V 35.4A 60Hz
208V 30.7A 60Hz
CONNECT WITH COPPER WIRE ONLY
The CE901 is rated 8.5kW at 240V and requires a separate 40-
ampere circuit.
The flexible (4') armoured cable should be connected directly to
the junction box.
Do not cut the conduit.
A U.L. listed conduit connector must be provided at the junction
box.
Do not ground to a gas pipe.
Do not have a fuse in the grounding or neutral circuit.
Fuse both supply (phase) lines.
A time delay fuse or circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker box)
through flexible, armored or non-metallic sheathed, copper cable
(with grounding wire).
If codes permit and a separate grounding wire is used, it is
recommended that a qualified electrician determine that the
grounding path and wire gauge is in accordance with local codes.
US
Minimum
supply wire size
No.10 AWG
5