Installing of the chimney and fixing of the hood
When the hood is installed in recycling version the chimney has
to be positioned with the slots upwards. When the hood is in-
stalled in ducting version it has to be positioned in the opposite
way.
• Place the chimney on the frame and fix it to the upper part of it
with the earlier removed screws. When installing the hood in
recycling version make sure that the slots correspond to the air
outlet of the recycling air outlet piece 15.
• Open the lighting unit by slightly pulling the notch. Remove
the unit from the hood by sliding the fixing pivot.
• Remove the filter pushing it towards the back side of the hood
unit and simultaneously pulling downwards.
• Remove possible charcoal filters.
• In order to fix the hood body to the frame insert the 4 screws
12f in their seats. It is necessary to leave at least 4-5 mm gap
between the screw heads and the frame plate.
• Hook the hood canopy to the frame and turn it to the left until
it reaches the stop, then lock the screws immediately to prevent
the hood canopy from falling out accidentally.
• Connect to hood to the mains supply through a double pole
switch with at least 3 mm clearance between the contacts.
• Make sure that the connecting piece of the cable is correctly
put in the socket.
• Connect the Cmd-connectors of the controls.
• Connect the Lux-connectors of the lighting system.
• In the recycling hood put the charcoal filter in its place.
• Put the metal grease filter and the confort panel into their pro-
per seats.
EN
Electrical connection
1
Lux
Cmd
1 11