Remote Controls Management - CDV Group DIGIWAY DWS102 Serie Manuel D'installation Et Utilisation

Systeme d'automatisme pour porte simple d'interieur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Obstacle management
If the door meets an obstacle:
When it opens : It stops and re-closes slowly. The next opening is done slowly for a new calibration and the
next closing is at standard speed.
When it closes : it stops, and re-opens. After the pause time it closes slowly. The next cycle will be standard.
If the obstacle remains, the door re-opens again, and remains open waiting for a command with the led blinking
RED/GREEN. After 5 min. another attempt of closing is done : if the obstacle is still present the door re-opens
and the cycle starts again.
If the operator is used for disabled persons doors, [ in compliance with the Regulation EN 12650-1, EN
12650-2 ], set Dip5 in ON position and adjust the two trimmers V.Close and V.Open in order to set the
min. trip time of the door according to the following table:
Door lenght
750 mm
850 mm
1000 mm
1200 mm
By setting Dip5 in ON position, the min. time of slowing down in closing ( last 10°) is set at 1,5 Sec. and
the max static motor torque, measured at 25 mm to the main closing edge, will be set at 67N.
Adjust the T.Pause for a waiting time not less then 5 sec.
Attention : Disabled persons doors must be identified with proper indications.
The operator is equipped with a superheterodyne receiver with a Keeloq® Hopping Code security protocol.
It can hence detect only compatible remote controls.
NOTE : The transmitters has no effect unless a calibration of the door has been successfully effected.
Before memorising the transmitters it's advisable to set the switch in Position II " door free ".
Memorising
Follow the following procedure to memorise the remote controls into the receiver internal memory:
1 - Keep the button P1 pressed down for 4 sec. until the led LP starts to flash GREEN;
2 - Release P1 and push the key of the transmitter which has to be memorised and verify LP which has to do a
longer pulse and after blinks again, waiting for more transmitters;
3 - Push the keys of all the transmitters to memorise;
4 - At the end, if within 6 sec. no more transmitters are activated the LP comes back to GREEN stable and the
procedure finishes.
Pag. 30
Disabled persons setting
50 Kg
60 Kg
3,0 s
3,1 s
3,1 s
3,1 s
3,2 s
3,4 s
3,8 s
4,2 s

Remote controls management

Door weight
70 Kg
80 Kg
3,2 s
3,3 s
3,2 s
3,4 s
3,7 s
4,0 s
4,5 s
4,8 s