Out B1: is an open-drain output which becomes low in battery-low status
Electrolock ( ELS ) outputs NO, COM, NC: Dry outputs contact for electric lock. A 500 mA 12 V
output is available at the terminals 20, 21. Use an external source of power if the current requested by
the electric lock is higher.
Battery: The operator is equipped with a 12 Vdc rechargeable battery, connected to operate in power
fealure status. It can operate for about 600 cycles thanks to its charge of 1,3 Ah.
Attention : rechargeable batteries have an operating temperature in the range 0° / +°50°C.
To ensure proper battery operation it's advisable the use in air-conditioned rooms.
UK
T.Pause
Close
ON 1 2
3
4
5
6
speed
P1
Open
speed
L1
L1 L2
L3 L4
1 2 3 4 5 6
NOTE - The 2 trimmers are set-in factory for the minimum value of opening
and closing speed.
At the end of the actuation force setting, they have to be adjusted for the best
value needed by the installation.
1 - Close completely the door;
2A - To change only the Closing Actuation Force, by increasing the set-in
factory or current value, rotate clockwise the trimmer CLOSE SPEED up to
the needed value and rotate anti-clockwise the trimmer OPEN SPEED up to
its MINIMUM value.
2B - To change only the Opening Actuation Force, by increasing the set-in
factory or current value, rotate clockwise the trimmer OPEN SPEED up to the
needed value and rotate anti-clockwise the trimmer CLOSE SPEED up to its
MINIMUM value.
2C - To change both the values of Actuation Force in opening and
closing increasing the set-in factory or current values rotate clockwise both
the trimmer OPEN SPEED and CLOSE SPEED up to the needed values
4 - Push and keep pushed the button P1 until the external led does a RED
FLASH and becomes STABLE GREEN : at that point both the values of
Actuating Force have been memorized and the trimmer become back to their
previous function of speed adjusting
5 - Adjust the trimmer CLOSE SPEED and OPEN SPEED according to the
installation necessities.

Actuation force adjust

It's possible to adjust separately the actuation force of the motore during both the
motions opening and closing in the approaching to the limits. For this function the
2 trimmers Close Speed and Open Speed are used to adjust the actuation force
assuming for a while a double function.
This can be usefull when the door is not perfectly balanced and doesn't reach the
limits with the set-in factory adjustments.
Procedure
A CDV Group product
MIN
MAX
MIN
MAX
Close Speed
Open Speed
MIN
MAX
MIN
OPEN SPEED
CLOSE SPEED
MIN
MAX
MIN
CLOSE SPEED
OPEN SPEED
MIN
MAX
MIN
OPEN SPEED
CLOSE SPEED
P1
8 SEC. BLINKS
1 FLASH
GREEN
RED
MIN
MAX
MIN
MAX
Close Speed
Open Speed
MIN
MAX
T. Pause
MAX
MAX
MAX
STABLE