Mains connection

/
*
Provide the potential equalisation (Fig. 4 pos. 3) between the device and the
mobile home or the caravan. Use a green/yellow cable with a minimum cross-
section of 4 mm². The potential equalisation does not replace the protective
conductor in the mains cable.
Potential equalisation
yellow/ green minimum 4 mm²
Connect to a conducting par t of the
mobile home or the caravan
Fig. 17: Mains connection / potential equalisation
Connect the 230 Volt output (Fig. 4 pos. 2) of the power
supply with the on-board distribution of your mobile home or
caravan. Connect the green/yellow cable to the earth circuit!
The 230 volt circuit breaker of the electric supply serves as
mains protection, and is connected directly on the input side
to supply socket of the mobile home or caravan.
Fig. 18:
230 V output
Check that all the connections are firm and secure. As the last
step, make the mains connection via the female connector of
the mains cable (Fig. 4 pos. 1). The socket on the device is
provided with a locking. When connecting the plug, make
sure that the locking engages. In order to remove the plug,
the locking must be released by lightly raising its wing.
Fig. 19:
230 V input
! "