Connecting a 12-pole plug connector
Fig. 13 shows the contacts available in the 12-pole plug
connector (view of device side). Connect the 12-pole plug
connector to the starter battery and supply battery in
accordance with the connecting diagram. Make sure that
the contact pins engage securely with the plug connector!
Loose contact pins can lead to malfunctions or short-
circuiting. The fuses protect the circuits. They should be
installed near the plus terminals of the batteries.
Fig. 13: 12-pole connector
1 .
*
Insert the 12-pole plug connector into the socket provided on the device (Fig.
10, pos. 4).
&
*
*
16
2
4mm
17
2
0,75mm
18
2
19
0,75mm
20
2
6mm
21
22
23
24
2
4mm
25
26
2
6mm
27
Fig. 14: Connection diagram 12-pole plug connector
! "
Lerchenfeldstr. 9 87600 Kaufbeuren Tél. : +49(0)8341 / 9764-0 Fax : +49(0)8341 / 67806
0
#
*
+ charging current
red
2A
D+ generator
brown
B+ measuring cable/ test
+ supply
minus
blue
red
12 V battery
12 V battery
(start)
(supply)
#
43