Replacement of the demineralisation
cartridge
Always unplug the unit before removing the
water tank. Do not touch the water in the base
en
during operation!
Option A: replace the resin
• Turn around the tank and open the turn-lock (18). The
demineralisation cartridge is attached to the inside of
the cap. Unscrew the cartridge turning it anti-clockwise
(19). Important: do not dispose of the tank cap!
• Open the cartridge (20).
• Throw the content into the waste (Attention! Thrown
out resin can make the floor slippery!) (21a).
• Cut the bag open at the marked point (22a).
• Insert the piece of styrofoam into the provided opening
(23).
• Put the open bag over the cartridge and fasten it to the
cartridge right at the top using the rubber band (24).
• Pour the replacement resin into the cartridge (25)
• Remove the bag, rubber band and styrofoam piece
(26).
• Close the cap (27).
• Screw the cartridge on the water tank cap (28). Close
the tank cap well, place the tank on the lower part, and
insert the vapour outlet (29).
• Soak the new granules for 24h before use! The resin
must soak up water to reach full performance!
Option B: replace the whole cartridge
• Turn around the tank and open the turn-lock (18). The
demineralisation cartridge is attached to the inside of
the cap. Unscrew the cartridge turning it anti-clockwise
(19). Important: do not dispose of the tank cap!
• Throw the whole cartridge into the waste (21b)
• Unpack the new cartridge (22b)
• Screw the cartridge on the water tank cap (28). Close
tank cap well, place the tank on the lower part and
insert vapour outlet (29).
20
RZ_BD_Ultrasonic 7137/38.indd
• Soak the new cartridge for 24h before use! The resin
must soak up water to reach full performance!
Cleaning/Maintenance
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
• Switch of the appliance and unplug it from the socket
before cleaning it (30).
• Clean the water tank and the reservoir regularly once
a week. When operating with preheating every two
weeks (31).
• Use decalcification agents found in stores everywhere
to remove deposits from the fogging chamber regularly
(32). Rinse out the decalcification agent thoroughly
with plenty of water.
Attention
• Make sure that no water gets into the lower part of the
main body (33).
• Clean the inner parts with a soft cloth. Do not use any
solvents or aggressive cleaning agents to clean the
appliance (34).
• Only use the brush to clean the membrane. This should
be done once a week.
• Change the water in the tank at least once a week.