1.2 Installation
Fuels
The equipment can be used with fuels detailed in the followings. This way the "low-
smoke" and trouble-free operation can be secured. Use only dry wood with
moisture of maximum 20% and lignite briquette.
Types of fuels
Hard wood
Soft wood
Brown-coal
Filling quantities 6 kW
- Split billet: max. Length: 33 cm
max. two billets per filling, appr. 1.4 kg
- Lignite briquette: max. 1.5 kg
Adjustment of the burning air:
Warming up, kindling
Wood
Browncoal
Putting out of working
Wood
Browncoal
Cooking:
The device meets the test of cooking stove EN 12815.
The primary air control should be set according to Table 1
for cooking "cooking" and with the maximum specified
below. Amounts of fuel to operate. The pot must be set to
the predetermined location of the hot plate (Fig.). Avoid
overcooking and fat splashes.
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with
preventive chemicals, furthermore paper and cardboard. For kindling please use
wood scrapings or grill starter but never use liquid auxiliaries!
Heating value
Filling quantities 8 kW
- Split billet: max. Length: 33 cm
max. two billets per filling, appr. 1.9 kg
- Lignite briquette: max. 2.2 kg
primary air
Fuel
door down
Nominal heating
performance
Nominal heating
performance
order
Cooking
Table 1
25
appr. kJ/kg
19.500
14.600
11.500
Setting of
the
regulator
fuel selector
backside
III
H
I
H
II
K
0
K
H
III
K