Kohler Memoirs K-6918-0 Guide D'installation Et D'entretien page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting (cont.)
Symptoms
Cause
B. Low water
pressure.
C. Improper waste
line venting.
2.
Leaks
A. Gaskets not
from
positioned
behind
correctly.
bowl.
3.
Bowl is
A. Threaded rods are
loose on
protruding too far
the
from wall.
threaded
rods.
B. Fasteners are not
tight.
Warranty
Need help? Contact the Customer Care Center at 1-800-456-4537.
For care and cleaning and other information visit kohler.com/clean.
This product is covered under the KOHLER
Limited Warranty.
For a hardcopy of warranty terms, contact the Customer Care Center.
USA/Canada: 1-800-4KOHLER (1-800-456-4537)
Kohler Co.
Recommended Action
B. Raise the water level in the
tank to the marked
waterline by turning the fill
valve white knob on the fill
valve in the tank clockwise
until the water level reaches
the waterline marked in the
tank (approximately 8" (203
mm) above the floor of the
tank).
C. Confirm the venting meets
code. Correct if needed.
A. Remove the bowl and
inspect all the gaskets.
Reposition the gaskets if
needed. Lubricate the
gaskets so they slide in or
over the mating part they
seal. Reinstall the bowl,
making sure the gaskets
stay in the correct positions.
A. Remove the bowl. Adjust
the threaded rods until they
are 3" (76 mm) from the
finished wall.
B. Make sure that the pegs are
oriented with the notches
facing down. Use the tool to
secure the bowl. Refer to
the "Install the Bowl"
section.
Warranty: One-Year
®
15
1391898-2-A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Memoirs k-5402k-0

Table des Matières