10 Dimensional drawings and technical specifications
Dimensional drawings of modules with low voltage
Standards
CE Directives
Standards
EC comformity assessment
Housing, modules
Mounting
Protective housing size W x H x D
Module housing size W x H x D
Type of ingress protection accord-
ing to EN60529
Maximum number of modules
Environmental conditions
Ambient temperature during opera-
tion
Storage temperature
Humidity
Cable cross-sections
Power supply
Pulses, frequency, analogue
Pt100
20
2004/22/EG (MID) Measuring Instruments Directive
2004/108/EG (EMC) Electromagnetic compatibility
2006/95/EG (LVD) Low voltage directive
EN 1434, EN 61000-6-2, EN 61000-6-3, EN 60950
Module B, DE-07-MI004-PTB029
With protective housing
On support rail or wall
140 x 202 x 83 mm
IP54
6 – 7, including 1 CPU and
1 supply module, max. 2
communications modules
+ 5... +55 °C, EN 1434 class C
0 °C ... 60 °C
Max. 95% rel. humidity, without producing condensation
2
0.8 ...2.5 mm
2
0.35 ...2.5 mm
2
0.8 ... 2.5 mm
(preferably large)
Without protective housing
On support rail
3 poles:
17.5 x 117.4 x 63.5 mm
3 poles: 240 V: 17.5 x 129.5 x 63.5 mm
4 poles:
22.5 x 117.4 x 63.5 mm
IP20
16, including 1 CPU and
1 supply module,
max. 2 communications modules
®
CALEC
energy master, Output 24V