7.2.3 Additional function 3: status indication via LEDs
If this function is active, the LEDs (18) will light perma-
nently when input F is activated.
This function can be used for visible status indica -
tion of the alarm system: For this purpose, connect
input F to an output which will deliver a control signal
(+12 V/0 V) according to the polarity adjusted for the
input (→ chapter 7.1) when the alarm system is
armed/disarmed.
The function is adjusted with the jumper (7):
jumper placed
function deactivated
jumper removed function activated
7.2.4 Additional function 4: audible status indication
If this function is active, activation/deactivation of input
F will be indicated by signal sounds: Upon activa tion, a
sequence of high audio signals will sound; upon deac-
tivation, a low and long audio signal will sound.
This function can be used for short audible status
indication of the alarm system: For this purpose,
connect input F to an output which will deliver a control
signal (+12 V/0 V) according to the polarity adjusted for
the input (→ chapter 7.1) when the alarm system is
armed/disarmed.
The function is activated/deactivated in the tone ad -
justing mode → chapter 9.
8 Setting the Siren Time
The maximum siren time can be set to 3 minutes or
10 minutes. After the siren time has elapsed, the siren
will be switched off, even if the alarm is not terminated.
However, the flashtube will remain activated for the
duration of the alarm.
Important: In case of outdoor installation of the siren,
the siren time must be limited in some countries (in
Germany to 3 minutes max.). Longer siren times will
cause noise disturbance which may be reported to
the police.
The maximum siren time is adjusted with the jumper (4):
jumper placed
siren time 3 minutes max.
jumper removed siren time 10 minutes max.
9 Tone Adjustment
The tone adjusting mode allows to adjust the sound of
the alarm tone by changing the parameters "frequency
range", "modulation type", and "modulation speed",
to select the type of the second alarm tone (→ chap-
ter 7.2.1), and to activate additional detection/
alarm functions.
Note: As the alarm tone selected is only audible when
an alarm is triggered, it is recommended to make the
tone adjustment prior to installation when the siren
should be connected to the terminals SPEAKER (10)
via a resistor (approx. 10 kΩ) to reduce the sound
level in the adjusting phase.
1) To activate the tone adjusting mode, remove the
jumper (8).
2) According to the adjustment desired, remove or
place the corresponding jumpers (1) to (7).
No. Setting
1
type of 2
nd
alarm tone
2
frequency range
falling
3
modulation
rising
4
modulation
modulation
5
speed
audible
6
status indication
(→ chapter 7.2.4)
alarm** if battery charg -
7
ing voltage is missing
(operating mode 3 only)
* If both modulation types are deactivated [jumpers (3) and (4)
removed], the alarm is a two-tone signal.
** corresponds to an alarm triggered via alarm input S
3) Replace the jumper (8).
After replacing the jumper (8), the tone adjusting mode
will be deactivated and the jumpers (1) to (7) will serve
again for setting the basic functions (→ chapters 5, 7,
and 8).
10 Specifications
Operating voltage: . . . . . 12 – 13.8 V
Current consumption
max.: . . . . . . . . . . . . . . . 1.2 A
Rechargeable battery
(not supplied): . . . . . . . . 12 V/2 Ah (max. dimensions
Sound pressure: . . . . . . 110 dB
Siren time max.: . . . . . . adjustable: 3 or 10 minutes
Flash energy: . . . . . . . . 10 Ws
Housing: . . . . . . . . . . . . outer housing: ABS plastic,
Protection class
of housing: . . . . . . . . . . IP 54
Ambient temperature: . . -25 °C to +55 °C
Dimensions: . . . . . . . . . 240 × 280 × 100 mm
Subject to technical modification.
All rights reserved by MONACOR
GmbH & Co. KG. No part of this instruction manual
may be reproduced in any form or by any means for
any commercial use.
placed
removed
opposed to
two-tone
the 1
st
alarm
signal
tone
low
high
activated
deactivated *
activated
deactivated *
high
low
deactivated
activated
deactivated
activated
177 × 66 × 34 mm)