Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
GB

8.2 Gamma correction

The adjusted value is Γ = 0.45. For the change un-
solder the 0 Ω resistors RA and RC resp. resolder
them correspondingly.
Gamma
1.0
0.45
0.2
X = soldered in
- = unsoldered
8.3 Shutter adjustment
There is no shutter ex factory. To enable the shutter
proceed as follows:
1) "J4" (closed in the factory) is opened.
2) According to below list by opening resp. closing of
the respective contacts the requested shutter
speed is selected:
Shutter
1
/
60
1
/
125
1
/
250
1
/
500
1
/
1000
1
/
2000
1
/
4000
1
/
10 000
14
RA
J5
close
sec
sec
close
sec
close
sec
close
open
sec
open
sec
sec
open
open
sec
-
X
-
RB
X
-
-
J6
close
close
open
open
close
close
open
open
RC
-
X
X
J7
close
open
close
open
close
open
close
open

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

19.0210

Table des Matières