INSTALLATION INSTRUCTIONS
1. Unbolt the unit from the shipping skid. Use a ratchet
with a 9/16 in. socket. Remove the unit from the
skid. This requires at least two people - one person
to walk the unit off the skid and one to help maintain
balance so the unit does not topple. Place the unit
where you plan to install it (at least 18 in. from any
wall or surface).
2. Place pre-drilled vibration pads (sold separately)
under each foot to avoid unnecessary vibration which
could damage the unit.
Using the mounting holes and the holes of the
vibration pads as a guide, drill holes into concrete
using a 3/8 in. masonry bit. Holes drilled must be at
least 5 in. into the concrete.
3. Insert mounting bolts. Use 3/8 in. x 5 in. wedge
anchors (not included) to secure the unit. Place
nut and washer on bolt. Thread nut onto bolt until
tops are fl ush. Strike bolt with hammer until nut and
washer are setting on top of the compressor foot.
Tighten nut using ratchet with a 9/16 in. socket until
anchor is set (using installation torque specifi cations
of bolt being used). Loosen nut to leave a 1/16 in.
(1.6 mm) gap for stress relief during unit operation.
1
2
3
Metal
Plate
Rubber
Pad
9
18 in.
Concrete
Anchor
1/16 in.
(1.6 mm)
kobalttools.com