9.
Fault
Display is off and no
signal from transmitter
Display is on but no signal
from transmitter
Display is off but there is a
signal from transmitter
Display does not show the
correct data

10. Cleaning, maintenance and repair

Cleaning
Clean, disinfect or sterilize sensor as needed
f
(CIP/SIP).
Maintenance
Regular maintenance is not required.

11. Disposal

Do not dispose of in household
f
waste.
Separate materials and dispose
f
of in compliance with nationally
applicable regulations.

12. Accessories

For mounting aids and other accessories see www.baumer.com.
14 / 54
Temperature measurement
RTD temperature sensor
Cause
Sensor not correctly connected
Device error
Short circuit
Wrong cabling
Incorrect temperature range
Operating Instructions
Options with FlexProgram
Sensor type
Temperature unit
Temperature range
Output limit
Damping
Data Logging
Sensor offset
Automatic cable compensation
Action
Check plug and power supply.
f
Dismount and send sensor to Baumer.
f
Remedy short circuit.
f
Connect the display and the
f
transmitter with the UnitCom cable.
Check programmed range limits.
f
Repair
Do not repair the sensor yourself.
Send damaged sensor to Baumer.
f
www.baumer.com