Configuration; Troubleshooting; Cleaning, Maintenance And Repair; Disposal - Baumer TE2 Manuel De Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.

Configuration

Configuration with FlexProgrammer
Disconnect loop supply.
f
Connect FlexProgrammer to sensor with the
f
white head cable.
Connect FlexProgrammer to PC and set
f
parameters (see FlexProgrammer instructions).
9.

Troubleshooting

Fault
No signals from transmitter Sensor not correctly connected
Incorrect signals from
transmitter

10. Cleaning, maintenance and repair

Cleaning
Clean, disinfect or sterilize sensor as needed
f
(CIP/SIP).
Maintenance
Regular maintenance is not required.

11. Disposal

Do not dispose of in household waste.
f
Separate materials and dispose of in compliance with nationally applicable regulations.
f

12. Accessories

For mounting aids and other accessories see www.baumer.com.
www.baumer.com
Cause
Short circuit
Device error
Incorrect temperature range
Operating Instructions
Temperature measurement
TE2
Compact RTD temperature sensor
Configurations:
Temperature range
Measuing unit
Sensor offset
Damping
Alarm value setting
Online Measuring
Temperature graph
Data logging
Action
Check plug and power supply.
f
Remedy short circuit.
f
Dismount and send sensor to Baumer.
f
Check programmed range limits with
f
FlexProgram.
Repair
Do not repair the sensor yourself.
Send damaged sensor to Baumer.