13. Technical data
13.1 Sensor
Environmental conditions
Process pressure
Ambient temperature
range
Humidity
Degree of protection
Vibration (sinusoidal)
(IEC 60068-2-6)
Process temperature See „Process conditions"
13.2 Transmitter
FlexTop® 2202 – Standard
Input
Output
Accuracy
Measuring range
Voltage supply range
Programmability
Factory settings:
Output range
Connection
Damping
Output at sensor
fault
www.baumer.com
See „Process conditions"
–40 ... 160 °C
–40 ... 85 °C
(with transmitter)
–30 ... 80 °C
(with display)
< 98 %, condensing
IP67
IP69K (with appropriate
cable)
1.6 mm p-p
(2 ... 25 Hz),
4 g (25 ... 100 Hz),
1 octave/min.
Pt100
4 ... 20 mA
Input: < ±0.25 °C
Output: < ±0.1 % of
output span
–200 ... 850 °C
(programmable)
Minimum span: 25 °C
8 ... 35 V DC
FlexProgrammer 9701
0 ... 120 °C
2-wire
0 s
Upscale 23 mA
Operating Instructions
Temperature measurement
CombiTemp™ TFRH/N
RTD temperature sensor
Sensor element, Pt100 DIN EN 60751
1/1 DIN Class B
1/3 DIN Class B
1/6 DIN Class B
1/1 DIN Class A
Response time T50
Sensor
diameter
6 mm
6/4 mm
8 mm
8/4 mm
FlexTop® 2212 and 2222
Input
Output
Accuracy
Measuring range
Voltage supply range 7 ... 40 V DC
Programmability:
FlexTop® 2212
FlexTop® 2222
Factory settings:
Output range
Connection
Damping
Output at sensor
fault
± (0.3 + 0.005 x t) °C
± 1/3 x (0.3 + 0.005 x t) °C
± 1/6 x (0.3 + 0.005 x t) °C
± (0.15 + 0.002 x t) °C
Air 3 m/s
Liquid
0.4 m/s
< 6.1 s
< 27.2 s
< 1.5 s
< 21.4 s
< 7.6 s
< 47.7 s
< 1.5 s
< 33.6 s
Pt100
2212: 4 ... 20 mA
2222: 4 ... 20 mA/HART
Input: < ±0.06 °C
Output: < ±0.025 % of
output span
–200 ... 850 °C
(programmable)
Minimum span: 10 °C
PC with FlexProgram
PC with FlexProgram /
HART terminal
0 ... 100 °C
2-wire
0 s
Upscale 23 mA
15 / 54