Technical Data - Baumer CombiTemp TFRH Manuel De Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13. Technical data

13.1 Sensor
Environmental conditions
Process pressure
Ambient temperature
range
Humidity
Degree of protection
Vibration (sinusoidal)
(IEC 60068-2-6)
Process temperature See „Process conditions"
13.2 Transmitter
FlexTop® 2202 – Standard
Input
Output
Accuracy
Measuring range
Voltage supply range
Programmability
Factory settings:
Output range
Connection
Damping
Output at sensor
fault
www.baumer.com
See „Process conditions"
–40 ... 160 °C
–40 ... 85 °C
(with transmitter)
–30 ... 80 °C
(with display)
< 98 %, condensing
IP67
IP69K (with appropriate
cable)
1.6 mm p-p
(2 ... 25 Hz),
4 g (25 ... 100 Hz),
1 octave/min.
Pt100
4 ... 20 mA
Input: < ±0.25 °C
Output: < ±0.1 % of
output span
–200 ... 850 °C
(programmable)
Minimum span: 25 °C
8 ... 35 V DC
FlexProgrammer 9701
0 ... 120 °C
2-wire
0 s
Upscale 23 mA
Operating Instructions
Temperature measurement
CombiTemp™ TFRH/N
RTD temperature sensor
Sensor element, Pt100 DIN EN 60751
1/1 DIN Class B
1/3 DIN Class B
1/6 DIN Class B
1/1 DIN Class A
Response time T50
Sensor
diameter
6 mm
6/4 mm
8 mm
8/4 mm
FlexTop® 2212 and 2222
Input
Output
Accuracy
Measuring range
Voltage supply range 7 ... 40 V DC
Programmability:
FlexTop® 2212
FlexTop® 2222
Factory settings:
Output range
Connection
Damping
Output at sensor
fault
± (0.3 + 0.005 x t) °C
± 1/3 x (0.3 + 0.005 x t) °C
± 1/6 x (0.3 + 0.005 x t) °C
± (0.15 + 0.002 x t) °C
Air 3 m/s
Liquid
0.4 m/s
< 6.1 s
< 27.2 s
< 1.5 s
< 21.4 s
< 7.6 s
< 47.7 s
< 1.5 s
< 33.6 s
Pt100
2212: 4 ... 20 mA
2222: 4 ... 20 mA/HART
Input: < ±0.06 °C
Output: < ±0.025 % of
output span
–200 ... 850 °C
(programmable)
Minimum span: 10 °C
PC with FlexProgram
PC with FlexProgram /
HART terminal
0 ... 100 °C
2-wire
0 s
Upscale 23 mA
15 / 54

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Combitemp tfrn

Table des Matières