12 Accessories

Connecting cable, straight
Please note:
For the four above connecting cables, the shielding wires are all terminated in the
connector. If you prefer to not have them terminated, please consult the factory.
Mounting bracket
part no. 10131521
Protective cover
part no. 10156878, material is acrylic glass (PMMA)
The protection cover can be easily mounted on the sensor's face. It protects the
glass front cover against welding splashes.

13 Troubleshooting

Error
Possible reason
The sensor does not
The sync. input or the teach-in
measure
wire is connected to +Vs
The receiving beam is covered by
an object / edge / step
No receiving signal (transparent or
highly reflective object)
The sensor has
Mutual optical interferences
incorrect measuring
between two or more sensors
values
Strong ambient light.
Semi transparent, transparent or
highly reflective objects
The sensor does not
Rough surface
reach the accuracy
Color edges
Resolution of the A/D converter in
the control unit
BA_OADM20I6_21I6_most.doc
12.06.2017
ESG 34FH0200G, 8-Pol, length 2 m, shielded
ESG 34FH0500G, 8-Pol, length 5 m, shielded
ESG 34FH1000G, 8-Pol, length 10 m, shielded
57/87
Correction
Connect sync. input or the teach-in wire to 0 V
Make sure that no object is in the receiving
field
Make sure that the laser spot falls on a diffuse
reflecting surface
Make sure that no other light spot is within the
receiving field of the sensor
Prevent ambient light with a shield
Make sure that the laser spot falls on a diffuse
reflecting surface
Possibly use a sensor with laser line
Mount the sensor the correct way
Read the manual of the control unit
Baumer
Frauenfeld, Switzerland