The following overview lists possible faults and the necessary
measures.
Symptom
The tacker is losing air.
Fasteners are not driven
in completely.
Triggering is not
possible.
Triggering without a
fastener being driven in
Possible cause
The fastening screws
are loose.
A seal is defective.
The operating
pressure is too low.
The driver tip on the
tacker is worn.
The operating
pressure is too low.
Moving parts are stuck
together with lubricant
following a long
storage period.
The magazine is
contaminated.
Corrective measure
 Tighten the fastening
screws.
 Notify customer services
(see page 35).
 Increase the operating
pressure.
 Notify customer services
(see page 35).
 Increase the operating
pressure of the
compressed air system
to the maximum
permissible level (see
page 15).
 Then actuate the trigger
several times.
 Clean the tacker and oil it
again.
 Set the maximum
operating pressure.
 Then actuate the trigger
several times.
 After triggering, set the
desired operating
pressure.
 Otherwise notify
customer services (see
page 35).
 Clean the magazine.