Technical Data
Input
Nominal voltage U
:
N
BG 5924:
IP 5924:
Nominal frequency:
Voltage range:
at 10 % residual ripple:
at 48 % residual ripple:
Nominal consumption
AC/DC 24 V:
AC 230 V:
Control voltage on Y1
AC/DC 24 V:
AC 230 V:
Control current:
Recovery time:
Output
Contacts
BG 5924.02, IP 5924.02:
BG 5924.04, IP 5924.04:
BG 5924.48, IP 5924.48:
The NO contacts are safety contacts.
The NC contacts 41-42 can only be used for monitoring.
Operate delay:
Release delay:
Contact type:
Thermal current I
:
th
Nominal output voltage:
Switching capacity
to AC 15
NO contact:
NC contact:
to DC 13
NO contact:
NC contact:
to DC 13
NO contact:
NC contact:
Electrical life
to AC 15 at 2 A, AC 230 V:
Permissible operating
frequency:
Short circuit strength
max. fuse rating:
line circuit breaker:
Mechanical life:
General Data
Operating mode:
Temperature range
operation:
storage :
altitude:
Clearance and creepage
distances
rated impuls voltage /
pollution degree
EMC
Interference suppression
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Climate resistance:
DC 24 V (only for variant /110)
AC/DC 24, 48 V
AC 110, 115, 230 V
AC/DC 24, 48 V
AC 110, 230 V
50 / 60 Hz
AC 0.8 ... 1.1 U
N
DC 0.9 ... 1.1 U
N
DC 0.8 ... 1.1 U
N
DC 1.2 W
AC 2 VA
3.5 VA
typ. DC 23 V
max. 45 V short pulse
typ. DC 45 mA
0.5 s
2 NO contacts
4 NO contacts
3 NO, 1 NC contacts
max. 100 ms
max. 35 ms
forcibly guided
max. 5 A (see limit curve)
AC 250 V
3 A / AC 230 V
IEC/EN 60 947-5-1
1 A / AC 230 V
IEC/EN 60 947-5-1
1 A / DC 24 V
IEC/EN 60 947-5-1
1 A / DC 24 V
IEC/EN 60 947-5-1
4 A / 24 V at 0.1 Hz
4 A / 24 V at 0.1 Hz
10
switching cycles IEC/EN 60 947-5-1
5
600 switching cycles / h
6 A gG / gL
IEC/EN 60 947-5-1
B 6 A
10 x 10
switching cycles
6
Continuous operation
- 25 ... + 55 °C
- 25 ... + 85 °C
< 2.000 m
4 kV / 2 (basis insulation) IEC 60 664-1
IEC/EN 62 061
Limit value class B
IP 40
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplastic with V0 behaviour
according to UL subject 94
Amplitude 0.35 mm
frequency 10 ... 55 Hz, IEC/EN 60 068-2-6
25 / 055 / 04
IEC/EN 60 068-1
Technical Data
Terminal designation:
Wire connection:
Wire fixing:
Mounting:
Weight:
BG 5924:
IP 5924:
Dimensions
Width x height x depth:
BG 5924:
IP 5924:
UL-Data
The safety functions were not evaluated by UL. Listing is accom-
plished according to requirements of Standard UL 508, "general use
applications"
Nominal voltage U
Ambient temperature:
Switching capacity:
NO contact:
NC contact::
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo
CSA-Data
Nominal voltage U
Ambient temperature:
Switching capacity:
Wire connection:
Technical data that is not stated in the CSA-Data, can be found
in the technical data section.
nfo
Troubleshooting
Failure
LED "Netz" does not light up
Device cannot be activated
EN 55011
Maintenance and repairs
- The device contains no parts that require maintenance.
- In case of failure, do not open the device but send it to manufacturer
for repair.
15
EN 50 005
Box terminal wih wire protection,
removable terminal strips
DIN rail
210 g
206 g
22.5 x 84 x 121 mm
70 x 90 x 59 mm
:
AC/DC 24 V
N
-15 ... +55°C
Pilot duty B300
5A 250Vac G.P.
5A 24Vdc
5A 250Vac G.P.
5A 24Vdc
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
:
AC/DC 24, AC/DC48V, AC110V, AC230V
N
-15 ... +55°C
3A 230Vac
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
Potential cause
Power supply not connected
- Safety relay is welded
(replace device)
- Start circuit Y1-Y2 not connected
IEC/EN 60 715
BG 5924 / 18.04.17 en / 849