• Estimated charge
time
Battery capacity
Charge timing 0% >>> 90%
*Lead battery corresponding : A lithium battery has a better starting performance (CCA) than a lead battery. That's why some
lithium battery manufacturers indicate the battery lead equivalent (EqPb) which corresponds to the capacity of a lead-acid battery
with the same starting performance. For instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid
battery of about 30 Ah.
• Protections :
The GYSFLASH 6.12 has comprehensive safety features to protect it against short-circuits and polarity reversals. It
has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has double
insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 6.12 is fitted with an integrated temperature probe that ensures that the charging current is adapted to the
ambient temprature to prevent internal electronics' overheating.
TROUBLESHOOTING
Troubleshooting
1
Indicator
blinks.
2
The indicator
is on.
Indicator
stays on even after pressing
3
button.
4
Indicator
blinks.
5
Indicator
stays on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSFLASH 6.12 LITHIUM
2 Ah
7 Ah
(6 Ah EqPb*)
(21 Ah EqPb*)
1 h
2 h 30
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
Charge failure, battery non recoverable.
Thermal protection.
Charger in sleep mode.
Charge interrupted by pressing
10 Ah
15 Ah
(30 Ah EqPb*)
(45 Ah EqPb*)
3 h
3 h
Causes
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
Change the battery and press
charge.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press button
ger to exit sleep mode.
Press
.
25 Ah
50 Ah
(75 Ah EqPb*)
(150 Ah EqPb*)
4 h
8 h
Solutions
or connect a battery to the char-
again to restart the charge.
EN
125 Ah
(375 Ah EqPb*)
18 h