Charging method D
STEP 1 - BOOST CHARGE
LED-indicator: YELLOW
The charger is in constant current mode (CC), charging with the maximum current until
battery voltage reach Top-Up level.
STEP 2 – TOP-UP CHARGE
The charger is in constant voltage mode. The LED-indication will be FLASHING YELLOW
during Top-up charge. The charger stays in this mode until the charge current decreases
to charge termination level or the Top-Up Charge Timer runs out. The battery is charged
to its full capacity at the end of this step
STEP 3 – FLOAT CHARGE
The LED-indication on the charger is GREEN and the battery is fully charged.
The charger is in float mode. The charge voltage is at float level and the charger may
remain connected to the battery.
The charger will return to boost charge if the battery is used.
BATTERY NOT CONNECTED INDICATIONS
Battery not connected is indicated by FLASHING GREEN
Diagram: D
INDICATOR: YELLOW
Battery Voltage
Charge Current
Start Current
Low
Current Start-Up at Vbatt <2.6V/cell
Error Mode if <2.6V/cell after 10 minutes
Step 0
Start Timer
(10 min)
Step 1
Boost Charge
Safety Timer (72 hours)
LFP charger diagram
INDICATOR:
FLASHING YELLOW
Charge Voltage
Cut-Off Current
Step 2
Top-up Charge (max 1h)
10
Yellow
Yellow
Green
INDICATOR: GREEN
Charge Voltage
Step 3
Float Charge