If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
A damaged cable increases the risk of an electric shock.
3.8-
Residual risks
Even when the tool is used as prescribed it is not possible to eliminate all residual risk factors. The
following hazards may arise in connection with the tool's construction and design:
a. Damage to lungs if an effective dust mask is not worn.
b. Damage to hearing if effective hearing protection is not worn.
c. Health defects resulting from vibration emission if the power tool is being used over longer period
of time or not adequately managed and properly maintained.
3.9- Noise, vibrations and electromagnetic field information
a- Noise level
Wear hearing protection while operating the power tool.
The noise level has been measured in accordance with a standard test method (EN60745).
The declared noise level values are mentioned in the characteristics table.
b- Vibration level
The declared vibration total value has been measured in accordance with a standard test method and
may be used for comparing one tool with another.
The declared vibration total value may also be used in a preliminary assessment of exposure.
Warning! The vibration emission during actual use of the power tool can differ from the declared
total value depending on the ways in which the tool is used.
There is the need to identify safety measures to protect the operator that are based on an estimation of
exposure in the actual conditions of use (taking account of all parts of the operating cycle such as the
times when the tool is switched off and when it is running idle in addition to the trigger time).
Prolonged used of a tool (or other machines) may expose the operator to vibrations that may
product white finger disease (Raynaud's syndrome) or carpal tunnel syndrome.
These conditions reduce the hand's ability to feel and regulate temperature, produce numbness and
may cause nerve and circulation damage and tissue necrosis.
All factors that contribute to the white finger disease are not known.
Some of the factors mentioned in the development of the white finger disease are: cold weather,
smoking and diseases or physical conditions that affect blood vessels and blood transportation, as
well as, high vibration levels and long periods of exposure to vibration.
To help in the prevention and reducing the risk of the white finger disease, please note the
following:
-- wear gloves and keep your hands warm;
-- maintain a firm grip at all times, but do not squeeze the handles with constant pressure,
-- take frequent pauses
The operator should closely monitor the condition of their hands and fingers, and if any of the
symptoms appear, seek medical advice immediately.
c- Electromagnetic field
Warning! This machine produces an electromagnetic field during operation. This field may under
some circumstances interfere with active or passive medical implants. To reduce the risk of serious or
fatal injury, we recommend persons with medical implants to consult their physician and the medical
implant manufacturer before operating this machine