MAINTENANCE (cont.)
SPARK PLUG
CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR
REPLACE AS NEEDED.
Nozzle Adaptor
Figure 18 – Spark Plug Replacement
(For Models CP050EK-CP175FK)
- Remove upper shell (See Air Intake Filter, page 12).
- Remove fan (See Fan Blades, page 13).
- Remove ignitor wire from spark plug.
- Remove spark plug from nozzle adaptor using
medium Phillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
- Reinstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
Nozzle Adaptor
Ignitor Wire
Figure 19 – Spark Plug Replacement
(For Model CP210FK only)
- Remove upper shell (See Air Intake Filter, page 12).
- Remove fan (See Fan Blades, page 13).
- Remove ignitor wire from spark plug.
- Remove spark plug from nozzle adaptor using
mediumphillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
- Reinstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
15
Screw
Spark Plug
Ignitor Wire
Spark Plug
Spark Plug
Screw
Spark Plug
PHOTOCELL
Side Cover
Power
Switch
Photocell Wires
Bracket
Install Photocell
Incorrect
Figure 20 – Photocell Replacement
CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.
- Remove upper shell (See Air Intake Filter, page 12)
- Remove fan (See Fan Blades, page 13)
- Remove photocell from its mounting bracket.
- Clean photocell lens with cotton swab.
TO REPLACE: Remove side cover near power switch.
- Disconnect wires from power switch and remove
side cover.
- Disconnect wires from circuit board and remove
photocell.
- Install new photocell and attach wires to circuit board
- Replace switch wires to power switch and side cover.
- Replace fan and upper shell.
Switch
Screw
Wires
Photocell
Lens
Correct