ENGLISH
WARNING
!
Do not operate vacuum with damp or wet filters
or without all filters in place.
MAINTENANCE & CARE
Cleaning the Pre-Motor Filter
• The pre-motor filter protects the motor from debris.
• Turn power OFF. Unplug vacuum cord from electrical outlet.
Fig. 1 The pre motor filter is located underneath the filter cup
in the center of the round part of the Lock 'n Seal
lever.
Fig. 2 Remove the small round filter and any debris on top of
it. Rinse under warm water; air dry completely before
replacing.
Checking Rotating Floor Brush
and Drive Belt
Check your vacuum's rotating floor brush and drive belt
regularly for wear or damage.
• Turn power OFF. Unplug vacuum cord from electrical outlet.
• Place handle in low position and turn vacuum over so
bottom side is facing up.
Fig. 3 Using a screwdriver, remove the six screws and lift
brush cover off.
Fig. 4 Grasp rotating floor brush at both ends and lift.
Clean strings, hair and other debris from rotating floor
brush, motor pulley and drive belt areas.
Check drive belt for wear, cuts or stressed areas.
Fig. 5 Check air passageway for obstructions. Remove debris
from this area.
• Place drive belt back onto motor pulley and brush roll. Put
right side brush roll end cap back into the housing. Pull on
the brush roll applying tension to the drive belt. Put left side
end cap back in the housing.
• Reposition brush cover and fasten six screws back into
place.
Replace Drive Belt
• Turn power OFF. Unplug vacuum cord from electrical outlet.
• With rotating brush removed (follow first 4 steps of check
rotating floor brush and drive belt), grasp old drive belt and
remove from motor pulley. Discard old drive belt.
• Place new drive belt over motor pulley and stretch other end
over rotating floor brush in the space between the bristles.
Place ends of rotating floor brush down into slots.
• Turn rotating floor brush by hand in the direction of the motor
pulley. If properly installed, drive belt will center itself on
rotating brush.
• Reposition brush cover and fasten six screws back into
place.
14 www.sanitairecommercial.com
(Fig. 6)
Fig. 1
®
Fig. 3
Fig. 4
Fig. 6
Fig. 2
Pre-motor filter
Filtro premotor
Filtre à l'avant du moteur
Fig. 5
Motor pulley
Polea del motor
Poulie du moteur
Air passageway
Conducto de aire
Entrée d'air