Extended Menu - Comunello Automation QUAD-230V-2M Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
L1
PGM CODE
L2
FOTOTEST
L3
DECELERATION
L4
LEAVES DELAY
L5
RELEASE STROKE
L6
SLAM LOCK
L7
COURTESY LIGHT
LEV
MENU
1. REMOTE CODE PGM (Remote Programming of Radio Controls):
The control unit allows the transmission code to be programmed from a
distance without acting directly on the control unit SELECT key. Remote
programming of the Radio Remote Controls is performed as follows: send,
continuously for a time in excess of 10 seconds, the code of a previously
saved remote; at the same time the control unit switches to programming
mode as described above for LED L3 in the main menu. If a pedestrian code
previously stored in the control unit is transmitted continuously, the control
unit switches to programming of a new pedestrian code. The control unit is
factory set with transmission code programming from a distance disabled,
proceed as follows if you want to enable the function: make sure you have
enabled Extended Menu 1 (shown by 1 0 1 0 1 blinking of the LEV LED),
press the SELECT key to select blinking LED L1 then press the SET key, at the
same time LED L1 becomes steady on and programming will be completed.
Repeat the procedure if you want to restore the previous configuration.
2. FOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled. To enable the
test, proceed as follows: make sure you have enabled Extended Menu 1,
use the SELECT key to select blinking LED L2 then press the SET key, LED
L2 becomes steady on and the programming procedure will be completed.
Repeat the procedure if you want to restore the previous configuration.
3. DECELERATION:
As mentioned earlier, the control unit allows programming of a deceleration
stage during opening and closing. However, if no deceleration is required,
this stage can be inhibited. If, before excluding the deceleration stage it had
already been programmed using the Motor Times Programming function,
programming must be repeated from the beginning. If the deceleration stage
is to be excluded proceed as follows: make sure you have enabled Extended
Menu 1, use the SELECT key to select blinking LED L3 and then press the
SET key: LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you want to restore the previous configuration.
4. LEAVES DELAY:
(15 sec. max leaf delay programming). The control unit is factory set with
leaves opening and closing delay disabled (4 sec.). If the control unit is used
in the configuration for an automation with 2 operators, it may be necessary
to set a different leaves delay time; programming must be performed with
the gate closed as follows: make sure you have enabled Extended Menu
1, press the SELECT key to select blinking LED L4 then press the SET key
momentarily; now wait for a time equivalent to the desired time interval and
then press the SET key again momentarily, at the same time the fixed 4
second leaves opening delay and the closing delay for the programmed time
will be saved and LED L4 will remain steady on. If you want to deactivate this
function (without leaves delay), select blinking LED L4 and then press the SET
key twice consecutively in a time interval of 2 seconds, at the same time the
LED will switch off and the operation will be terminated.
5. RELEASE STROKE:
The control unit is factory set with the release stroke function disabled. To
enable the Release Stroke function at maximum power, proceed as follows:
make sure you have enabled Extended Menu 1, use the SELECT key to
select blinking LED L5 then press the SET key, LED L5 becomes steady on
and the programming procedure will be completed. If you wish to enable
the Release Stroke function at the power set with the "FORCE" trimmer,
repeat the procedure described above, press the SELECT key twice (LED
L5 will blink rapidly) rather than just once. Repeat the procedure if you
want to restore the initial configuration. This procedure makes it possible
to facilitate release of the gate lock and thus allow correct execution of the
opening stroke. With this function, before starting the opening stroke the
control unit sends a closing command for 2 seconds with the thrust force
associated with the selection made.
22
COMUNELLO ®Copyright 2014 - All rights reserved
6. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled. This
function consists in adding, in the presence of a deceleration stage during
ON
OFF
closing, 1 extra second at the maximum power or at the power selected
ON
OFF
with the "FORCE" trimmer, in such a way as to ensure positive engagement
OFF
ON
of the gate lock, if installed. If you want to enable the Slam Lock function
ON
OFF
at maximum power, proceed as follows: make sure you have enabled
ON
OFF
Extended Menu 1, use the SELECT key to select blinking LED L6 and then
ON
OFF
press the SET key: LED L6 becomes steady on and programming will be
completed. If you want to enable the Slam Lock function at the power set
ON
OFF
with the "FORCE" Trimmer, repeat the operation described by pressing the
1 FLASH
SELECT key twice (LED L6 will blink rapidly) rather than once. Repeat the
procedure if you want to restore the initial configuration.
7. PREFLASHING/COURTESY LIGHT:
The control unit is factory set with the Preflashing and Courtesy Light
functions disabled. If you want to enable the Preflashing function proceed
as follows: make sure you have enabled Extended Menu 1, use the SEL key
to select blinking LED L7 and then press the SET key: the LED becomes
steady on and programming will be completed. If you want to enable the
Courtesy Light function, repeat the operation described above, pressing
the SELECT key twice (the LED will blink rapidly) rather than once. Repeat
the procedure if you want to restore the initial configuration.
Preflashing Operation: the 24 ~ 4W max. Flashing Light output will
always switch on 3 seconds before the gate starts the closing operation.
Courtesy Light Operation: the 24 ~ 4W max. Courtesy Light output will
switch on for 3 minutes whenever an opening command is transmitted.

EXTENDED MENU 2

The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you want to enable the functions described in Extended
Menu 2, proceed as follows: select blinking LED LEV and press SET twice.
The LED will start blinking alternately 1 1 0 1 1 0 1 1 0. This means there is
a period of 30 seconds to select the functions in Extended Menu 2 using
the SELECT and SET keys and then, after a further 30 seconds, the control
unit will revert to the main menu.
L1
L2
L3
L4
L5
L6
L7
LEV
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L1
and press the SET key; at the same time LED L1 becomes steady on and
programming will be completed. With this function enabled at the end of
the movement the control unit will reduce operator force to zero gradually
in a 2 second interval. Repeat the procedure if you want to restore the
previous configuration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L2
and press the SET key; at the same time LED L2 becomes steady on
and programming will be completed. With this function enabled at the start
of each movement the control unit will modulate start-up of the operator,
gradually increasing the force from the minimum to the value set by the
"FORCE" trimmer during the first 2 seconds of operation. Repeat the
procedure if you wish to restore the previous configuration.
Note: when the Soft Start function is enabled, the control unit automatically
disables the Starting Torque function, while if Soft Start is disabled, then
Starting Torque is automatically enabled.
3. DS1 ALSO IN OPENING:
The control unit allows the operation of input DS1 to be modified. If you
want DS1 to operate also during opening (momentary stopping of the gate,
as soon as it is freed the control unit resumes the opening movement),
SOFT STOP
ON
SOFT START
ON
DS1 IN OPEN
ON
HOLD-TO-RUN
ON
FOLLOW ME
ON
PAUSE FLASHING
ON
ALWAYS CLOSE
ON
MENU
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2 FLASHIES