LINEA
POWER SUPPLY
2P+T 230V
50Hz
F1
F2
CN3
12.5V
24.5V
TRASFORMATORE
TRANSFORMER
230 / 24.5V - 0.4A; 12.5V - 0.17A
MOTORE 2
M
MOTOR 2
230V
50HZ
CN1
SET
SEL
CN4
MOTORE 1
MOTOR 1
M
230V
50HZ
ELETTROSERRATURA (contatto pulito N.O.)
ELECTRIC LOCK
LAMPEGGIANTE
FLASHING LIGHT
24V
4W
ALIMENTAZIONE FOTOCELLULE
PHOTCELL POWER
24V
CN2
ELS
FOTOCELLULA
ELS
PHOTCELL
DS 2 (N.C.) IN APERTURA
LAMP
FOT+
GND
FOTOCELLULA
PHOTCELL
DS2
DS 1 (N.C.) IN CHIUSURA
DS1
GND
PED
PP
ANT-
PULSANTE APRI-CHIUDI (N.O.)
PUSCH BUTTON (N.O.)
ANT+
PULSANTE PEDONALE (N.O.)
PEDESTRIANPUSH BUTTON (N.O.)
ANTENNA
COMUNELLO ®Copyright 2014 - All rights reserved