PROGRAMMING:
SELECT key: selects the type of function to store; the selection is indicated
by blinking of the LED.
Press the key twice to go to the desired function. The selection remains
active for 10 seconds shown by blinking of the LED; when this interval
elapses the control unit returns to the original state.
SET key: programs the information in accordance with the function type
preselected with the SELECT key.
IMPORTANT: the SET key function can be replaced by the remote if
programmed beforehand.
Programming enabled only when safety devices are not active.
L1
DELAY
Operator 1 delay
L2
STEP-BY-STEP
Step-by-Step
L3
TX CODE
Code entered
L4
CONDO
ON
L5
MOTOR TIME
Programmed time
L6
PAUSE TIME
With automatic closing
L7
PED. TIME
ON
LEV
MENU
MAIN MENU
The control unit is factory set to allow the selection of several important
functions.
1. DELAY:
In the default configuration the control unit is set up with "OPERATOR 2
DELAY" logic. To avoid having to disconnect the wiring in order to set a
delay for operator 1 rather than operator 2, proceed as follows: use the
SELECT key to select blinking LED L1 and then press the SET key: LED
L1 becomes steady on and programming will be completed. Repeat the
procedure if you want to restore the previous configuration.
2. STEP BY STEP:
In the default configuration the control unit is set with "Automatic" operating
logic enabled (LED n2 off); if the "Step-by-Step" operating logic is required
(LED n2 on), proceed as follows; use the SELECT key to select blinking
LED n2 and then press the SET key: LED n2 becomes steady on and
programming will be completed.
If the "Step-by-Step 1" operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to obtain
the quick blinking of LED. Repeat the procedure if you wish to restore the
previous configuration.
3. TX CODE (Remote control code):
Up to 120 remotes with different codes, either of the fixed or the rolling
code type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use the
SELECT key to select blinking LED L3. Press SET once; the LED will change
its blinking mode (longer 1 0 1 0) to show that the first level is being saved.
On sending the selected code with the desired remote, the LED will remain
steady on to indicate that programming has been completed. To save
the code for pedestrian opening / single leaf proceed as follows: use the
SELECT key to select blinking LED L3. Press SET twice consecutively; the
LED will change its blinking mode (1 1 0 1 1 0) to show that the pedestrian
code is being saved. On sending the selected code with the desired
remote LED L3 will remain steady on to indicate that programming has been
completed. If all 120 codes have been saved, repeating the programming
operation will cause all the programming LEDs to start blinking, to signal that
no further codes can be saved.
Deletion:
Use SELECT to go to LED L3; activate blinking of the code to be deleted
(CODE or PEDESTRIAN identified by the respective blinking); press and
hold down SET for > 5 s. After this interval the LED will switch off for 2
seconds and the procedure is completed. If all CODE and PEDESTRIAN
codes are deleted, the LED will remain off. If only PEDESTRIAN codes
remain stored, the LED blinking mode will change (1 1 1 1 0 1 1 1 1 0).
Rule of the first saved Remote control:
When programming remotes the following rule is applied: if the first remote
to be saved is of the rolling code type, the receiver will subsequently
accept only rolling code remotes, thus providing enhanced anti-intrusion
security; if the first remote to be saved is a fixed code type, the receiver will
subsequently accept both fixed code remotes and rolling code remotes,
although only the fixed part of the latter will be controlled (thus effectively
relinquishing the security of the rolling code system).
4. CONDO:
The Condominium function means that during the opening movement or
during the pause time the control unit will not respond to commands sent
by Pushbuttons or remotes. In contrast, during the closing movement a
command sent by the Pushbuttons or the remotes will reverse the direction
of movement. This operating mode is invaluable when the automation
includes a loop detector. In the default configuration the control unit is set
with the Condominium function disabled; if the Condominium function is
required, proceed as follows: use the SELECT key to select blinking LED L4
and then press the SET key: LED L4 becomes steady on and programming
will be completed. Repeat the procedure if you want to restore the previous
configuration.
Operator 2 delay
Automatic
5. MOTOR TIME:
No code
(Programming motor time of the operators with max 4 minutes). The control
OFF
unit is factory set with a preset motor time of 30 seconds without deceleration.
If the motor time of the operators must be changed, programming must be
30 sec.
carried out with the gate closed as follows: use the SELECT key to select
Without automatic closing
blinking LED L5 and then press the SET key momentarily; the operator
OFF
will start the opening movement; when the desired deceleration starting
ON
point is reached press the SET key again; at the same time the operator
will decelerate and reach the desired position; press SET to terminate the
opening cycle. Thereafter LED L5 will start blinking rapidly; now repeat the
motor time and deceleration programming procedure for the closing cycle.
If you do not require the control unit to perform the deceleration, during
programming, when the open-close cycle has been completed press the
SET key twice consecutively rather than just once. During programming,
instead of the SET key on the control unit you can use the button on the
remote, providing the remote has been saved beforehand.
6. PAUSE TIME:
(Automatic closing time programming 4 min. max.) The control unit is
factory set with automatic closing disabled. If you wish to enable automatic
closing proceed as follows: use the SELECT key to select blinking LED
L6 and press the SET key momentarily; now wait for a time equivalent to
the time interval desired; press the SET key again momentarily and at the
same time the automatic closing time will be saved and LED L6 will remain
steady on. If you wish to restore the initial condition (no automatic closing)
select blinking LED L6 and then press the SET key twice consecutively in
a time period of 2 seconds. The LED will switch off and the operation will
be completed. During programming, instead of the SET key on the control
unit you can use the button on the remote, providing the remote has been
saved beforehand.
7. PED TIME (Programming of pedestrian motor time, 4 minutes max):
The control unit is factory set with a preset Operator run time (Pedestrian)
of 10 seconds without deceleration. If the pedestrian run time must be
changed, programming must be carried out with the gate closed as follows:
use the SELECT key to select blinking LED L7 and then press the SET
key momentarily; the Operator will start the opening movement; when the
desired deceleration starting point is reached press the SET key again;
LED L7 will start blinking more slowly and the Operator will decelerate; on
reaching the desired position press SET to terminate the Opening cycle.
At this point LED L7 returns to the normal blinking speed and the Operator
restarts in the Closing movement; repeat the operations described above
for the Closing movement. If you do not require the control unit to perform
the deceleration, during programming, when the open-close cycle has been
completed press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the
main menu functions. If you want to enable the functions described in
Extended Menu 1, proceed as follows: select blinking LEV LED and
press SET once. The LED will start blinking. This means there will be 30
seconds to select the functions of Extended Menu 1 using the SELECT
and SET keys; once an additional 30 seconds have elapsed the control
unit reverts to the main menu.
COMUNELLO ®Copyright 2014 - All rights reserved
21