Quick Start Guide
HMI – TX200
For Your Safety
Intended Use
The HMI (Human Machine Interface) TX207 is used to control, operate and moni-
tor machine processes.
The devices may only be used as described in these instructions.
Any other usage shall be considered improper and Turck shall not be held liable
for any resulting damage.
General Safety Instructions
The device may only be assembled, installed, operated, parameterized and
maintained by professionally-trained personnel.
The device only meets the EMC requirements for industrial areas and is not
suitable for use in residential areas.
The device may only be used in accordance with applicable national and
international regulations, standards and laws.
Product Description
Device overview
See fig. 1
A
B
C
176 mm/
136 mm/
29 mm/
6.90"
5.35"
1.14"
Functions and Operating Modes
The HMI (Human Machine Interfaces) TX207 combines control, operation and
monitoring in a full-scope control thanks to the CODESYS V3 PLC with inte-
grated visualization. The CODESYS 3 control of the TX500 has the functions
PROFINET controller, EtherNet/IP™ scanner and Modbus TCP as well as Modbus
RTU master. Additionally the TX207 can be used as Modbus TCP as well as
Modbus RTU slave.
Additional functions
Ethernet TCP/IP or UDP/IP communication
OPC-UA server and client
Serial communication via RS232, RS485 and RS422
Mounting
See fig. 2 and 3
A = TX200
B = cut-out
Screw each fixing screw until the bezel corner gets in contact with the panel.
The maximum tightening torque is 0.75 Nm.
Connecting
Connectors and slots
See fig. 4
Connector/Slot
Function
1
Power supply
2
X2
RS422/485 + CAN (COM2/CAN0)
3
X3
RS422/485 + CAN (COM3/CAN1)
4
X4
RS232 + RS232 (COM1/COM4)
5
X5
USB port
6
X6
USB port
7
X7
Ethernet port 0 (10/100/1000 Mbit)
8
X8
Ethernet port 1 (10/100 Mbit)
9
S1
RS485 + CAN port configuration (DIP)
10
S2
RS485 + CAN port configuration (DIP)
NOTE
Devices of protection class III according to EN 61140 or Class 2 according to UL
standards:
All connections are SELV connections.
Power supply
Connect the device to the voltage supply according to fig. 5 and 6.
DANGER
Wrong selection of power supply
Danger to life due to overvoltage and electric shock!
Only operate devices at SELV-power supplies.
Grounding the device
The minimum conductor cross-section for the ground connection is 1.5 mm².
Connect terminal 3 on the power supply terminal block to ground.
H
L
T
147 mm/
187 mm/
5 mm/
5.79"
7.36"
0.19"
ATTENTION
Unprotected electronic circuits
Destruction of electronics!
Do not open the device under voltage.
Serial interfaces/CAN interface
RS232 (X4)
See fig. 7
Pin
RS232
1
GND
2
TxD
3
RxD
4
RTS
5
CTS
6
GND
7
TxD
8
RxD
RTS
9
CTS
10
RS485/CAN (X2 and X3)
See fig. 8
Pin
RS485
1
n.c.
2
3
4
5
6
Terminating resistor
7
GND
8
Terminating resistor
9
Y (TX+)
10
Z (TX-)
11
A (RX+)
12
B (RX-)
RS485 (CAN port configuration – DIP switches S1 and S2)
position
Description
1
CAN terminating resistor
2
CAN terminating resistor
3
RS485 halfduplex
4
RS485 halfduplex
5
RS485 terminating resistor
6
RS485 terminating resistor
Maintenance
The devices must be cleaned at regular intervals with a damp cloth.
Repair
The device must not be repaired by the user. The device must be decommis-
sioned if it is faulty. Observe our return acceptance conditions when returning
the device to Turck.
Disposal
The devices must be disposed of correctly and must not be included in
normal household garbage.
Approvals and standards
Compliance
The products have been designed in compliance with:
EN 61000-6-2, EN 61000-6-4
EN 61000-4-2 to 4-6, EN 61000-4-8, EN 61000-4-11, EN 61000-4-29
© Hans Turck GmbH & Co. KG | 100002509 2018-05 DE EN FR
CAN
GND
Terminating resistor
CAN-H
CAN-L
Terminating resistor
n.c.