ELECTRICAL CONNECTION

• Before connecting the appliance make sure that the voltage and frequency rated on the data plate
conform to those of the mains supply.
Note: The installer must set the torque selector switch to the appropriate voltage depending on the
weight (see page 17) and dimensions of the gate/door which is to be automated. The safety standards
indicate a maximum thrust at the head of the gate equal to 15 kg.
• Connect the control wires, the security devices, the motor cables and other 230Vac devices. Connect
the power supply cable to the device
Terminal board connections
1
Inner conductor for the radio receiver antenna.
(The antenna must be connected using a coaxial cable RG58 with an impedance of 50Ω).
2
Outer conductor for the radio receiver antenna.
TAL (contact normally open) limited opening button (only for motor 1).
3
TA (contact normally open) Opening button in input.
4
TC (contact normally open) Closing button in input.
5
TD (contact normally open) Dynamic button in input "Open-Close".
6
7-8
Common for all inputs.
TB (contact N.C.) Blocking button in input (The opening of this contact will interrupt the
9
cycle until a new movement command is given).
10
FTCI (contact N.C.) Safety and control devices in input (photocells invert the travel direction
when an obstruction is detected). The opening of this contact will provoke a travel direction
inversion during closure due to the cutting in of the safety device.
FTCS (normally closed contact) Safety and control devices in input (photoelectric cells stop-
11
ping the gate when an obstruction is detected). The gate will start moving again automatically
once the object or obstruction has been removed and after the pause time has elapsed
until it reaches a travel limit (only in the automatic mode) and always during closing.
12-14
Common for all inputs and outputs (negative).
15-16
Second channel exchange contact in output (only for a 2-channel receiver card).
17
FCA1 (normally closed contact) opening travel limit switch in input 1.
18
FCC1 (normally closed contact) closing travel limit switch in input 1.
19
Common for all inputs.
FCA2 (normally closed contact) opening travel limit switch in input 2.
20
FCC2 (normally closed contact) closing travel limit switch in input 2.
21
22
Common for all inputs and outputs (negative).
Indicator lamp 24Vac 3W.
23-24
Electric locking device 12Vac 15W max. (only while opening).
25
24Vac 10W in output, powering external devices.
26
Night light in output 230Vac 40W.
27-28
Warning lights in output 230Vac 40W (intermittent or continuous activation).
29-30
Motor M2 in output Opening- Closing- Common.
31-32-33
Motor M1 in output Opening- Closing- Common.
34-35-36
Electronic programmer power supply 230Vac 50/60Hz.
37-38
Electronic programmer earth wire 230Vac 50/60Hz.
39
40
Motor earthing wire (output).
41
Motor earthing wire (output).
NOTE:
ALL UNUSED NC CONTACTS MUST BE JUMPED
(with the exception of the travel limits excluded via software "see Programming procedure")