TROUBLESHOOTING

If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Advance Service Center
immediately for service.
TRIPPING THE CIRCUIT BREAKER
The Circuit Breaker (20) is located on the Control Panel; it protects the electrical circuit and brush motor from damage due to overload conditions. If
the circuit breaker is tripped try to determine the cause.
Brush Circuit Breaker (5 Amp) Possible cause may be:
1
Debris wrapped around the brush drive (remove debris)
2
Brush setting too low (adjust to proper brush setting)
3
Electrical short circuit (have your Advance Service Center or qualifi ed electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again. If the
circuit breaker trips repeatedly, call your Advance Service Center for service.

POOR WATER PICKUP

Possible causes may be:
1
Recovery Tank Full (empty recovery tank)
2
Open recovery tank drain hose (secure drain hose cap or replace)
3
Recovery hose not connected at vacuum shoe (connect hose to vacuum shoe)
4
Recovery hose is kinked or damaged (replace the hose)
5
Recovery tank cover gasket leak (replace gasket)
6
Debris caught in vacuum shoe or recovery hose (clean vacuum shoe and recovery hose)
INADEQUATE SOLUTION FLOW
Possible causes may be:
1
Solution tank empty (fi ll solution tank)
2
Solution lines or screen clogged (fl ush lines and screen)
3
Nozzle selector is turned to a position between maintenance and restoration (turn knob to full left or full right)
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Model No.
Voltage/frequency
Rated Current
Protection Class (electrical)
Protection Grade
Sound Pressure Level (IEC 60704-2-1)
Total Weight
Vibrations at the Hand Controls (ISO 5349-1)
Solution Tank Capacity
Recovery Tank Capacity
A-12 - FORM NO. 56041602 - AquaClean
AquaClean
AquaClean
56265003
56265000
V/Hz
120 / 50-60
Amp
13.3
--
74.3dB LpA, 3dB KpA
lbs/kg
166 / 75.29
m/s
0.72m/s
2
8 gal (30l)
6 gal (23l)
16ST
16XP
AquaClean
18FLX
56265001
120 / 50-60
14
--
74.3dB LpA, 3dB KpA
203 / 92
0.72m/s
2
2
11 gal (41l)
9 gal (34l)
AquaClean
18ST
56265008
120 / 50-60
14
--
74.3dB LpA, 3dB KpA
203 / 92
0.72m/s
2
11 gal (41l)
9 gal (34l)