6. Initial Operation
a) Installation/Setup
The assembly and the installation of the device must be carried out by a specialist who is
familiar with the hazards and the relevant regulations. Repairs, operation and maintenance of
the product may only be carried out by qualified personnel.
When choosing a location for your device, make sure to avoid vibration, dust, hot and cold
temperatures and dampness. Furthermore, no powerful transformers or motors must be set up
in the vicinity of the device.
When installing/setting up the device, make sure that the connection cable is not crushed and
cannot be damaged by any sharp edges.
Do not use the device on flammable surfaces or in the proximity of flammable objects. Maintain
a distance of at least 0.5m to flammable objects.
Make sure that the fog output opening is not directed towards persons, animals or open fires.
The emerging hot steam may lead to burns (keep a safety distance of 0.5 m)!
Ensure a sufficient ventilation of the device; maintain a free zone of 0.2m around the device and
never cover the ventilation openings.
Always place the appliance on a stable base. Ensure that it does not fall down and causes injury.
The device's operating position is horizontal (max. tilt: 15°) so that the tank does not leak when
filling and operating the device.
The device must be mounted out of normal reach.
During installation and service work, the area underneath the place of installation must be
cordoned off.
The area or equipment of installation must be designed in such a way that it can support the
tenfold rated load for at least one hour without being deformed permanently.
In addition, the device must be secured with a second independent safety fixture besides the
actual installation fixture when installed with the installation strap. If the main supports fail, no
part of the installation should be allowed to fall down.
During mounting, all the relevant regulations (in particular BGV C1, formerly VGB 70 and EN
60598-2-17) must be observed.